文献速递神经肿瘤

非增强影像用于治疗与未治疗脑膜瘤的监测

Noncontrast imaging for the surveillance of treated and untreated meningiomas.
PubMed 文献 · J Neurosurg · 2025-01-31

该回顾性研究纳入136例成人脑膜瘤患者(65例治疗、71例未治疗),比较单独轴位T2WI与CE-T1WI联合T2WI评估肿瘤生长、尺寸和静脉窦侵犯的相关性与准确性。单独T2WI检测生长与联合评估近乎完全一致(κ=0.945),准确性97.8%、特异性100%、敏感性92.3%;作者结论认为无增强T2WI可评估肿瘤尺寸、检测生长和静脉侵犯,可靠性与准确性相当。

要点

  • 单独T2WI检测肿瘤生长与CE-T1WI联合T2WI近乎完全一致(κ=0.945)。
  • 单独T2WI检测生长的准确性97.8%、特异性100%、敏感性92.3%。
  • 颅底、治疗及大(>20 mm)脑膜瘤亚组中两种评估方式无显著差异。

核心结论

  • 在治疗和未治疗的脑膜瘤患者中,无增强T2WI可评估肿瘤尺寸、检测生长和检测静脉侵犯,其可靠性与准确性与当前临床实践使用CE-T1WI联合T2WI相当。

研究设计与样本

  • 回顾性识别136例成人患者(65例治疗和71例未治疗脑膜瘤),每例有两次至少间隔6个月的MRI扫描。
  • 每例患者两次CE-T1WI序列按时间配对,两次T2WI序列同样配对并独立评估。
  • 配对扫描由一名神经放射科医生和一名高级放射学受训者盲法评估临床数据。
  • 评估肿瘤位置、尺寸、生长和静脉侵犯;瘤周水肿仅在T2WI上评估。
  • 使用Cohen kappa(κ)、组内相关系数(ICC)和Bland-Altman图评估CE-T1WI联合T2WI与单独T2WI评估之间的一致性。

主要发现

  • T2WI检测到36个肿瘤生长,而CE-T1WI联合T2WI评估检测到39个。
  • 单独T2WI评估的生长与CE-T1WI联合T2WI一起评估的生长显示近乎完全一致(κ=0.945)。
  • 单独T2WI的准确性为97.8%,特异性为100%,敏感性为92.3%。
  • 放射科医生之间肿瘤尺寸的评分者间相关性为良好至优秀(ICC>0.843)。
  • 观察者1的T2WI与CE-T1WI测量前后径和横径的评分者内一致性良好(ICC>0.883),观察者2为(ICC>0.767)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Patients with meningiomas require serial MRI for surveillance of tumor size and growth rate. The cost and resource requirements for contrast-enhanced MRI include intravenous cannulation, the contrast agent, risk of adverse reaction, and the time needed to acquire, review, and report the additional sequences. With repeated doses, gadolinium is known to accumulate in neural tissues. The authors compared the correlation and accuracy of axial T2-weighted imaging (T2WI) sequences alone for assessing tumor growth, dimensions, and dural venous sinus invasion compared with the current clinical practice of assessing both contrast-enhanced T1-weighted imaging (CE-T1WI) and T2WI sequences. METHODS: The authors retrospectively identified 136 adult patients (65 patients with treated and 71 patients with untreated meningiomas) with two MRI scans obtained at least 6 months apart. For each patient, the two CE-T1WI sequences separated by time were paired, as were the two T2WI sequences, and assessed independently. The paired scans were assessed by a neuroradiologist and advanced radiology trainee blinded to clinical data. Tumor location, dimensions, growth, and venous invasion were evaluated. Peritumoral edema was assessed on T2WI only. Agreement between assessments on both CE-T1WI and T2WI sequences compared with T2WI alone was evaluated using Cohen's kappa (κ), the intraclass correlation coefficient (ICC), and Bland-Altman plots. RESULTS: Growth was detected in 36 tumors on T2WI compared with 39 when both CE-T1WI and T2WI were assessed. Growth assessed on T2WI alone showed near-perfect agreement with growth assessed on CE-T1WI and T2WI together (κ = 0.945). T2WI alone had an accuracy of 97.8%, specificity of 100%, and sensitivity of 92.3%. Interrater correlation between the radiologists for tumor dimensions was good to excellent (ICC > 0.843). Intrarater agreement between T2WI and CE-T1WI measurements of anteroposterior and transverse tumor dimensions was good (ICC > 0.883 for observer 1, > 0.767 for observer 2). There was substantial agreement between venous invasion on T2WI and both CE-T1WI and T2WI (κ = 0.771). Subgroup analysis for skull base (58.1%), treated (47.8%), and large (> 20-mm diameter; 38.2%) meningiomas did not show any significant difference in agreement between T2WI only and CE-T1WI and T2WI assessments of growth, venous invasion, or tumor dimension. CONCLUSIONS: In patients with treated and untreated meningiomas, unenhanced T2WI can assess tumor dimensions, detect growth, and detect venous invasion with comparable reliability and accuracy to the current clinical practice of using both CE-T1WI and T2WI.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Nguyen LV, Kam NM, Li SJ, et al. Noncontrast imaging for the surveillance of treated and untreated meningiomas. J Neurosurg. 2025. PMID: 39889285. doi:10.3171/2024.9.JNS241425

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。