文献速递神经肿瘤

基于机器学习的血浆常压质谱在小鼠胶质瘤模型中的诊断准确性

Diagnostic Accuracy of Ambient Mass Spectrometry with Blood Plasma in a Murine Glioma Model Using Machine Learning.
PubMed 文献 · World Neurosurg · 2025-01-09

研究采用GL261胶质瘤细胞构建同种异体颅内原位小鼠模型,于移植前及移植后3、7、14天采集血浆,用探针电喷雾电离质谱(PESI-MS)获取质谱并比较肿瘤组(n=7)与对照组(n=8),再用机器学习逻辑回归模型评估诊断性能。结果发现16个显著质谱峰,多因素逻辑回归筛选出5个关键质谱,区分肿瘤的灵敏度为0.875、特异度为0.943,受试者工作特征曲线下面积为0.981,优于单个质谱分析。作者认为PESI-MS联合机器学习诊断血浆变化可能是准确检测恶性胶质瘤的有前景方法。

要点

  • 小鼠胶质瘤模型血浆PESI-MS联合机器学习诊断灵敏度0.875、特异度0.943。
  • 受试者工作特征曲线下面积0.981,优于单个质谱分析。
  • 共鉴定16个显著质谱峰,多因素逻辑回归筛选出5个关键质谱峰。

核心结论

  • 作者认为,血浆PESI-MS联合机器学习诊断可能是准确检测恶性胶质瘤的有前景方法。

研究设计与样本

  • 采用同种异体颅内原位小鼠模型,使用GL261胶质瘤细胞。
  • 于颅内移植胶质瘤细胞(肿瘤组,n=7)或注射磷酸盐缓冲液(对照组,n=8)前及移植后3、7、14天采集血浆。
  • 用探针电喷雾电离质谱(PESI-MS)获取质谱,比较对照组与肿瘤组,并探索移植后3、7、14天三个时间点的质谱变化。
  • 评估基于机器学习的逻辑回归诊断算法的性能,以明确其用于早期诊断的潜在价值。

主要发现

  • 在肿瘤组与对照组之间鉴定出16个显著质谱峰。
  • 多因素逻辑回归分析揭示5个关键质谱,区分肿瘤的灵敏度为0.875、特异度为0.943。
  • 受试者工作特征曲线下面积为0.981,优于单个质谱分析。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Malignant glioma progresses rapidly and shows poor prognosis, but clinically applicable blood plasma-based biochemical tumor markers remain lacking. This study aimed to develop a diagnostic system using probe electrospray ionization mass spectrometry (PESI-MS) and a machine-learning logistic regression model to detect plasma changes at various time points in a murine glioma model. METHODS: We used a syngeneic intracranial orthotopic murine model with GL261 glioma cells. Blood plasmas were collected before and 3, 7, and 14 days after intracranial transplantation of glioma cells (tumor group, n = 7) or injection of phosphate-buffered saline (control group, n = 8). Mass spectra from those samples were obtained using PESI-MS and compared between control and tumor groups. We explored changes in mass spectra at the 3 time points (3, 7, and 14 days) after transplantation. The performance of machine-learning logistic regression-based diagnosis algorithm was evaluated to clarify the potential utility for early diagnosis. RESULTS: Sixteen significant mass spectrum peaks were identified between the tumor and control groups. Multiple logistic regression analysis revealed 5 key mass spectra, achieving sensitivity of 0.875 and specificity of 0.943 for tumor discrimination. The area under the receiver operating characteristic curve was 0.981, outperforming analyses of individual spectra. CONCLUSIONS: These results indicate that PESI-MS combined with machine learning-based diagnostics in blood plasma could be a promising approach to accurate detection of malignant glioma.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Kazama H, Hanihara M, Yoshimura K, et al. Diagnostic Accuracy of Ambient Mass Spectrometry with Blood Plasma in a Murine Glioma Model Using Machine Learning. World Neurosurg. 2025. PMID: 39709093. doi:10.1016/j.wneu.2024.123577

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。