单步3D打印辅助下良性蝶眶肿瘤切除后采用患者特异性聚醚醚酮植入物行颅眶重建
本研究回顾性分析了2019至2024年在本机构接受单步切除良性蝶眶肿瘤并用聚醚醚酮患者特异性植入物行颅眶重建的11例患者,整合三维模型于术中导航并在照护点3D打印,术后影像显示88.9%患者植入物位置最佳且突眼指数消退,但36.4%出现手术并发症,作者认为该方案可行且美学、视觉与肿瘤学结果良好,尽管并发症风险显著。
要点
- 单步切除与聚醚醚酮患者特异性植入物重建在蝶眶肿瘤中可行
- 术后88.9%患者突眼指数消退且植入物位置最佳
- 36.4%患者出现手术并发症,最常见为伤口愈合不良(2例)
核心结论
- 单步切除与聚醚醚酮患者特异性植入物重建蝶眶肿瘤可行,结合了手术技术、虚拟植入物设计与3D打印技术,尽管术后并发症风险显著,本队列仍获得了良好的美学、视觉与肿瘤学结果。
研究设计与样本
- 回顾性分析2019至2024年在本机构接受单步切除良性蝶眶肿瘤并用聚醚醚酮患者特异性植入物行颅眶重建的患者,共纳入11例。
主要发现
- 脑膜瘤WHO 1级是最常见肿瘤类型(81.8%),多数患者以突眼为首发体征(63.6%)。
- 术后颅脑影像显示聚醚醚酮植入物位置最佳且突眼指数消退者占88.9%。
- 4例(36.4%)患者出现手术并发症,其中2例(50%)曾接受过肿瘤切除手术,最常见并发症为伤口愈合不良(n=2)。
- 1例(9.1%)患者在6个月随访时观察到肿瘤复发。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Computer-aided design (CAD) and computer-aided manufacturing (CAM) techniques have paved the way for single-step resections and cranio-orbital reconstructions with patient specific implants in spheno-orbital tumors. Here, we present our interdisciplinary maxillofacial and neurosurgical workflow and a case series of patients treated with this integrated approach. METHODS: Patients, who underwent single-step resection of benign spheno-orbital tumors and cranio-orbital reconstruction with polyetheretherketone (PEEK) patient specific implants (PSI) from 2019 to 2024 in our institution were included. Three dimensional models of the tumor, the skull, the implants and the cutting guides were integrated into intraoperative neuronavigation and 3D printed at the point of care (POC) for surgical planning. Clinical data was retrospectively analyzed, pre- and postoperative Exophthalmic index (EI) was radiologically determined. RESULTS: Eleven patients met inclusion criteria. Meningioma WHO grade 1 was the most common tumor entity (81.8%). In a majority of patients, exophthalmos was the presenting sign (63.6%). Postoperative cranial imaging revealed an optimal position of the PEEK implants with regredient EI in 88.9%. Four (36.4%) patients, of whom two (50%) had undergone prior tumor resections, suffered from surgical complications. The most commonly recorded complication was impaired wound healing (n = 2). Tumor recurrence was observed in one (9.1%) patient at six months follow-up. CONCLUSIONS: Single-step resection and reconstruction in spheno-orbital tumors with PEEK PSIs is feasible and combines surgical expertise, virtual implant design and 3D printing techniques. Favorable aesthetical, visual and oncological outcomes were achieved in this cohort, despite a significant risk for postoperative complications.
引用
- Rezai A, Pöppe JP, Gaggl A, et al. Single-step 3D printing aided cranio-orbital reconstruction with patient specific polyetheretherketone implants after resection of benign spheno-orbital tumors. Acta Neurochir (Wien). 2024. PMID: 39666097. doi:10.1007/s00701-024-06393-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。