文献速递神经重症

利用视网膜小动脉与小静脉比值评估颅内压

Utilizing retinal arteriole/venule ratio to estimate intracranial pressure.
PubMed 文献 · Acta Neurochir (Wien) · 2024-11-08

这项单中心前瞻性队列研究在神经重症监护病房纳入40例格拉斯哥昏迷评分≤8分且接受有创压力监测的成人患者,用眼底镜视频结合深度学习算法计算视网膜小动脉与小静脉比值(A/V比值)并与颅内压(ICP)相关分析。结果显示ICP>15 mmHg时A/V比值与ICP呈显著负相关,但考虑眼内压未改善模型,敏感性分析灵敏度80.08%、特异度22.51%、AUC 0.6389。作者认为无创眼底镜检查是检测ICP升高的潜在工具,但图像质量和诊断特异度等挑战仍存,需更大规模多中心研究验证。

要点

  • ICP>15 mmHg时A/V比值与ICP呈显著负相关(回归斜率-0.0659,95%CI [-0.0665;-0.0653],p<0.001)。
  • ICP≤15 mmHg时A/V比值未见显著变化。
  • 考虑眼内压未改善模型,敏感性分析灵敏度80.08%、特异度22.51%、AUC 0.6389。

核心结论

  • 与作者既往工作一致,无创眼底镜检查是检测颅内压升高的潜在工具。
  • 图像质量和诊断特异度等挑战仍存,需更大规模多中心研究验证其效用,标准化可能提升该技术的临床适用性。

研究设计与样本

  • 单中心前瞻性队列研究,于2020年9月至2021年5月在欧登塞大学医院神经重症监护病房开展。
  • 纳入格拉斯哥昏迷评分≤8分且接受有创压力神经监测的成人患者,每日采集眼底镜视频并用深度学习算法分析,计算A/V比值并与ICP行混合效应线性回归分析。
  • 共入组40例患者,最终分析纳入15例。

主要发现

  • ICP范围为-1至31 mmHg(均值10.9,标准差5.7),眼内压范围为4至13 mmHg(均值7.4,标准差2.1)。
  • ICP>15 mmHg时A/V比值与ICP呈显著负相关(回归斜率-0.0659,95%CI [-0.0665;-0.0653],p<0.001);ICP≤15 mmHg时A/V比值未见显著变化。
  • ICP>眼内压时亦呈类似显著相关(回归斜率-0.0055,95%CI [-0.0062;-0.0048],p<0.001)。
  • 将眼内压纳入考虑并未改善模型。
  • 敏感性分析显示灵敏度80.08%、特异度22.51%,AUC为0.6389。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 图像质量和诊断特异度等挑战仍存。
  • 需更大规模多中心研究验证其效用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Intracranial pressure (ICP) control is important to avoid secondary brain injury in patients with intracranial pathologies. Current methods for measuring ICP are invasive and carry risks of infection and hemorrhage. Previously we found correlation between ICP and the arteriole-venous ratio (A/V ratio) of retinal vessels in an outpatient setting. This study investigated the usability of fundoscopy for non-invasive ICP estimation with the addition of intraocular pressure (IOP) in patients in a neuro-intensive care unit (NICU). METHODS: This single-center prospective cohort study was conducted at the NICU of Odense University Hospital from September 2020 to May 2021. Adult patients with a Glasgow Coma Score of 8 or less, who underwent invasive pressure neuromonitoring were included. Fundoscopy videos were captured daily and analyzed using deep learning algorithms. The A/V ratio was calculated and correlated with ICP. The data was analyzed using mixed-effect linear regression models. RESULTS: Forty patients were enrolled. Fifteen were included in the final analysis. ICP ranged from -1 to 31 mmHg (mean: 10.9, SD: 5.7), and IOP ranged from 4 to 13 mmHg (mean: 7.4, SD: 2.1). The A/V ratio showed a significant negative correlation with ICP > 15 mmHg (regression slope: -0.0659, 95%-CI: [-0.0665;-0.0653], p < 0.001). No significant change in A/V ratio was observed for ICP ≤ 15 mmHg. A similar significant correlation was found for ICP > IOP (regression slope: -0.0055, 95%-CI: [-0.0062;-0.0048], p < 0.001). Taking the IOP into account did not improve the model. The sensitivity analysis showed a sensitivity of 80.08% and a specificity of 22.51%, with an AUC of 0.6389. CONCLUSION: In line with our previous work, non-invasive fundoscopy is a potential tool for detecting elevated ICP. However, challenges such as image quality and diagnostic specificity remains. Further research with larger, multi-center studies are needed to validate the utility. Standardization may enhance the technique's clinical applicability.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Nortvig MJ, Andersen MCS, Eriksen NL, et al. Utilizing retinal arteriole/venule ratio to estimate intracranial pressure. Acta Neurochir (Wien). 2024. PMID: 39514087. doi:10.1007/s00701-024-06343-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。