电磁导航提高特发性正常压力脑积水患者脑室腹腔分流术的准确性和减少并发症:单中心临床经验
这项单中心回顾性研究比较了电磁导航与标准解剖标志法放置脑室腹腔分流管的效果,纳入31例标准置管和50例电磁导航置管的特发性正常压力脑积水患者。电磁导航组1级置管比例更高(92% vs 71%,P=0.03),导管尖端位置更准确(P<0.001),冠状面和矢状面导管偏斜角度更小,穿刺次数更少、手术时间更短、脑实质出血发生率更低(P<0.01),2年随访分流故障更少(2% vs 26%,P=0.0003)。
要点
- 电磁导航组1级分流管置入比例为92%,标准组为71%(P=0.03)。
- 电磁导航组冠状面导管偏斜角19.69° vs 标准组24.2°(P<0.0001),矢状面21.75° vs 39.3°(P<0.01)。
- 2年随访期间电磁导航组分流故障率为2%,标准组为26%(P=0.0003)。
核心结论
- 在特发性正常压力脑积水患者的脑室腹腔分流术中,使用电磁导航可提高导管置入准确性、减少术后并发症和分流故障率,并提供精确和个体化的手术治疗。
研究设计与样本
- 单中心回顾性研究,纳入31例采用解剖标志标准置管的特发性正常压力脑积水患者和50例采用电磁导航引导置管的患者,随访时间为术后3、6、12、24个月或至分流失败。
主要发现
- 电磁导航组1级分流管置入比例为92%,标准组为71%(P=0.03);3级置入比例电磁导航组为2%,标准组为13%(P=0.068)。
- 电磁导航组导管尖端位于室间孔的位置显著更准确(P<0.001),冠状面导管偏斜角度为19.69°,标准组为24.2°(P<0.0001);矢状面为21.75°,标准组为39.3°(P<0.01)。
- 电磁导航组穿刺次数更少、手术时间更短、脑实质出血发生率更低(P<0.01)。
- 2年随访期间电磁导航组分流故障率为2%,标准组为26%(P=0.0003)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Ventriculoperitoneal (VP) shunt surgery is the primary treatment for patients with idiopathic normal pressure hydrocephalus (iNPH). This study compared the outcomes of VP shunt placement using electromagnetic (EM) navigation versus standard methods in patients with iNPH, focusing on catheter accuracy and postoperative complication rates. METHODS: This retrospective study included 31 patients with iNPH who underwent standard shunt placement using anatomical landmarks and 50 patients who underwent EM-guided shunt placement. Parameters assessed included shunt placement grade, catheter tip position, catheter angle, puncture attempts, operative duration, postoperative infection rates, intraparenchymal hemorrhage rates, and shunt malfunction rates. Patients had follow-ups at 3, 6, 12, and 24 months after surgery or until shunt failure. RESULTS: In the EM-guided group, a higher percentage of grade 1 shunt placements (92% vs. 71%, P = 0.03) and fewer grade 3 placements (2% vs. 13%, P = 0.068) were observed. The catheter tip position at the foramen of Monro was significantly more accurate (P < 0.001), with smaller lateral catheter deviation angles in both coronal (19.69° vs. 24.2°, P < 0.0001) and sagittal (21.75° vs. 39.3°, P < 0.01) sections. The EM-guided group had fewer puncture attempts, shorter operative durations, lower incidence of intraparenchymal hemorrhage (P < 0.01), and fewer shunt malfunctions over the 2-year follow-up period (2% vs. 26%, P = 0.0003). CONCLUSIONS: The use of EM navigation in VP shunt placement for patients with iNPH improves catheter placement accuracy, reduces postoperative complications and shunt malfunction rates, and provides precise and individualized surgical treatment.
引用
- Ma X, Fan X, Yang W, et al. Electromagnetic Navigation Improves Accuracy and Reduces Complications of Ventriculoperitoneal Shunts in Patients with Idiopathic Normal Pressure Hydrocephalus: A Single-Center Clinical Experience. World Neurosurg. 2024. PMID: 39577631. doi:10.1016/j.wneu.2024.11.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。