颅骨测量与颅骨形态如何影响帕金森病脑深部电刺激术中丘脑底核靶点坐标
该回顾性研究纳入77例在越南胡志明市Nguyen Tri Phuong医院和大学医学中心接受双侧丘脑底核脑深部电刺激术的帕金森病患者,分析颅骨测量与丘脑底核靶点坐标的相关性。丘脑底核X坐标与第三脑室宽度(r=0.4)和水平弧(r=0.42)相关性最强,回归方程R²=0.32,颅骨形态不对称可能影响坐标。
要点
- 男性颅骨测量尺寸大于女性,存在显著性别差异。
- 丘脑底核X坐标与第三脑室宽度(r=0.4)和水平弧(r=0.42)相关性最强。
- 颅骨形态不对称可能影响丘脑底核坐标,提示个体化规划的重要性。
核心结论
- 颅骨测量和第三脑室宽度与丘脑底核坐标显著相关,尤其是X坐标;研究强调脑深部电刺激手术规划中个体化颅骨测量考虑的重要性,以优化电极放置和治疗结果。
研究设计与样本
- 回顾性研究,纳入77例在越南胡志明市Nguyen Tri Phuong医院和大学医学中心接受双侧丘脑底核脑深部电刺激术的帕金森病患者,采用Pearson相关和多变量线性回归分析颅骨测量与丘脑底核靶点坐标。
主要发现
- 颅骨测量存在显著性别差异,男性尺寸更大。
- 丘脑底核X坐标与水平弧(r=0.4)和第三脑室宽度(r=0.42)相关性最强。
- 线性回归方程:X(mm)=0.967+0.202×第三脑室宽度(mm)+0.024×水平弧(mm),R²=0.32。
- 颅骨形态显示可能的不对称,影响丘脑底核坐标。
临床怎么用
- 作者认为,颅骨测量和第三脑室宽度与丘脑底核坐标显著相关,脑深部电刺激手术规划中应重视个体化颅骨测量考虑,以优化电极放置和治疗结果。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This study investigates the correlation among craniometric measurements, skull morphology, and subthalamic nucleus (STN) target coordinates in DBS surgery. METHODS: We conducted a retrospective study of 77 Parkinson disease patients who underwent bilateral STN-DBS surgery at Nguyen Tri Phuong Hospital and University Medical Center in Ho Chi Minh City, Vietnam. Craniometric measurements and STN target coordinates were analyzed using Pearson correlation and multivariate linear regression. The coordinates of the STN were compared between 2 hemispheres in the same patient, based on skull morphology indices, including the Cephalic Index and the Cranial Vault Asymmetry Index. RESULTS: Significant gender-based differences were observed in craniometric measurements, with males exhibiting larger dimensions. STN coordinates demonstrated correlations with various cranial measurements, notably with X-coordinates correlating most strongly with horizontal arc and third ventricle width (r = 0.4 and r = 0.42, respectively). The linear regression equation: X (mm) = 0.967 + 0.202∗ Third ventricle width (mm) + 0.024∗Horizontal arc (mm) with R2 = 0.32. Skull morphology revealed potential asymmetries affecting STN coordinates. CONCLUSIONS: Craniometric measurements and third ventricle width correlate significantly with STN coordinates, particularly the X-coordinates. Our study highlights the importance of individualized craniometric considerations in DBS surgery planning to optimize electrode placement and therapeutic outcomes.
引用
- Pham TA, Luong CM, Dao PD, et al. How Do Craniometric Measurements and Skull Morphology Influence Subthalamic Nucleus Target Coordinations in Deep Brain Stimulation Surgery for Parkinson Disease? World Neurosurg. 2024. PMID: 39481841. doi:10.1016/j.wneu.2024.10.095
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。