文献速递功能神经外科

低剂量CT引导下三叉神经痛甘油射频毁损术在手术室外进行的辐射暴露与安全性

Radiation exposure and safety in low-dose CT-guided glycerol rhizotomy for trigeminal Neuralgia outside the operating room.
PubMed 文献 · Acta Neurochir (Wien) · 2024-11-22

回顾性分析本院经皮三叉神经节毁损术患者,分为透视引导组(32例)和CT引导卵圆孔穿刺组(30例),CT组中位有效剂量0.21 mSv,卵圆孔穿刺成功率100%,仅3例轻微面颊血肿;作者认为低剂量CT引导在放射科进行对患者辐射可忽略、对人员无辐射,快速简单精准且并发症风险极低。

要点

  • CT引导组卵圆孔穿刺成功率为30/30(100%),透视组为31/32(96.9%)。
  • CT引导组中位有效剂量0.21 mSv,透视组为0.022 mSv。
  • CT引导组即时疼痛缓解25/30(83.3%),1个月时22/30(73.3%)缓解。

核心结论

  • 在放射科进行的低剂量CT引导经皮三叉神经节毁损术对患者辐射暴露可忽略,对人员无辐射暴露。
  • 该方法快速、简单、精准,并发症风险极低。

研究设计与样本

  • 回顾性分析本院接受经皮三叉神经节毁损术的患者,按透视引导或CT引导卵圆孔穿刺分为两组。
  • 辐射剂量评估排除了数据不完整的病例。
  • 研究纳入透视引导组32例手术和CT引导组30例手术。

主要发现

  • CT引导组中位有效剂量为0.21 mSv,每例手术中位CT扫描次数为4.5次,中位手术时间为15分钟。
  • 透视引导组中位有效剂量为0.022 mSv,中位手术时间为15分钟。
  • CT引导组卵圆孔穿刺成功30/30(100%),透视引导组成功31/32(96.9%)。
  • CT引导组唯一并发症为3例轻微面颊血肿。
  • CT引导组即时疼痛缓解25/30(83.3%),1个月时22/30(73.3%)缓解,1个月缓解的18例中10例(55.6%)在两年后仍维持缓解。

临床怎么用

  • 作者认为低剂量CT引导经皮三叉神经节毁损术可在放射科进行,对患者辐射暴露可忽略且对人员无辐射暴露。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Percutaneous rhizotomy of the Gasserian ganglion is a well-established intervention for patients suffering from refractory trigeminal pain, not amenable to pharmacological management or microvascular decompression. Traditionally conducted under fluoroscopic guidance using Hartel's technique, this study investigates a modified approach employing low-dose CT guidance to achieve maximal procedural precision and safety with the emphasis on minimizing radiation exposure. METHODS: A retrospective analysis of patients undergoing percutaneous rhizotomy of the Gasserian ganglion at our institution was undertaken. Procedures were divided into fluoroscopy and CT-guided foramen ovale (FO) cannulation cohorts. Radiation doses were assessed, excluding cases with incomplete data. The study included 32 procedures in the fluoroscopy group and 30 in the CT group. RESULTS: In the CT-guided group, the median effective dose was 0.21 mSv. The median number of CT scans per procedure was 4.5, and the median procedure time was 15 min. Successful FO cannulation was achieved in all 30 procedures (100%). In the fluoroscopy group, the median effective dose was 0.022 mSv, and the median procedure time was 15 min. Cannulation of FO was successful in 31 of 32 procedures (96.9%). The only complications in the CT-guided group were three minor cheek hematomas. Immediate pain relief in the CT-guided group was reported in 25 of 30 procedures (83.3%), 22 of 30 (73.3%) provided relief at one month, and 10 of 18 (55.6%) procedures resulting in pain relief at one month continued to provide relief after two years. CONCLUSION: Low-dose CT-guided percutaneous rhizotomy conducted in the radiology suite carries negligible radiation exposure for patients and eliminates it for personnel. This method is fast, simple, precise, and carries a very low risk of complications.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Dostal J, Baxa J, Stepankova J, et al. Radiation exposure and safety in low-dose CT-guided glycerol rhizotomy for trigeminal Neuralgia outside the operating room. Acta Neurochir (Wien). 2024. PMID: 39576393. doi:10.1007/s00701-024-06364-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。