进展期弥漫性低级别胶质瘤瘤周区的弥散张量成像分析
该回顾性研究纳入5例弥漫性低级别胶质瘤患者,分析初始弥散张量成像(DTI)在1年后FLAIR肿瘤进展区域内的信号特征。结果显示进展区域内平均各向异性分数较低(P=0.03),而平均弥散率、轴向弥散率和径向弥散率较高(P=0.03),提示DTI异常可能反映尚未在FLAIR上显示的肿瘤浸润。
要点
- 5例患者1年后均确认肿瘤进展,进展区域内存在预先存在的DTI信号异常。
- 进展区域平均各向异性分数较健康对侧低(P=0.03)。
- 进展区域平均弥散率、轴向弥散率和径向弥散率较健康对侧高(P=0.03)。
核心结论
- 本研究显示1年后肿瘤进展区域存在预先存在的DTI信号异常,这些异常可能对应尚未在FLAIR上可见的肿瘤浸润。
- 作者认为这可能有助于预测肿瘤进展并调整治疗策略。
研究设计与样本
- 回顾性研究,纳入5例符合标准的弥漫性低级别胶质瘤患者。
- 纳入标准:初始影像含25方向DTI、T1和FLAIR,1年随访时有FLAIR。
- 排除初始影像前2年内完成手术、放疗或化疗的患者。
主要发现
- 5例患者均在1年时确认肿瘤进展。
- 所有患者进展区域内均显示预先存在的DTI信号异常。
- 进展区域平均各向异性分数较健康对侧低(P=0.03)。
- 进展区域平均弥散率、轴向弥散率和径向弥散率较健康对侧高(P=0.03)。
临床怎么用
- 作者认为DTI信号异常可能有助于预测肿瘤进展并调整治疗策略。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Diffuse low-grade gliomas are rare brain tumors transforming to higher grade even with surgery, chemotherapy, and radiotherapy. Their preferential infiltration of white matter tracts, beyond tumor boundaries on fluid-attenuated inversion recovery (FLAIR), make difficult to plan focal treatment such as surgery or radiotherapy and monitor response to chemotherapy. Diffusion tensor imaging (DTI) might reflect this infiltration of white matter tracts. The aim of our study is to assess how DTI signal in the peritumoral zone might be modified before FLAIR tumor progression appears at 1-year follow-up. METHODS: The study retrospectively enrolled 5 patients who met inclusion criteria: DTI with 25 directions, T1 and FLAIR at initial imaging; FLAIR at one-year follow-up. Patients with surgery, radiotherapy, and chemotherapy completed less than 2 years before initial imaging were excluded. FLAIR tumor progression, named progression mask, was assessed by subtracting tumor masks between initial imaging and one-year follow-up. Initial DTI signal was analyzed within this progression mask and compared with the healthy contralateral side. RESULTS: Tumor progression was confirmed for the 5 patients at 1 year. All patients showed pre-existing DTI signal abnormalities within the progression mask. Mean fractional anisotropy (P = 0.03) was lower in the progression mask, whereas mean diffusivity, axial diffusivity, and radial diffusivity mean (P = 0.03) was higher in the progression mask, compared with the healthy side. CONCLUSIONS: This study shows pre-existing DTI signal abnormalities in regions with tumor progression at 1 year. Such abnormalities could correspond to a tumor infiltration not yet visible on FLAIR. This might be helpful to predict tumor progression and allow to adapt the therapeutic strategy.
引用
- Chiche D, Taillandier L, Blonski M, et al. DTI Analysis of the Peritumoral Zone of Diffuse Low-grade Gliomas in Progressing Patients. World Neurosurg. 2024. PMID: 39489335. doi:10.1016/j.wneu.2024.10.111
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。