文献速递小儿神经外科与脑积水功能神经外科

Watkins与Watkins2.0:用于正常压力脑积水和失代偿性长期站立性巨脑室步态评估的智能手机应用

'Watkins' & 'Watkins2.0': Smart phone applications (Apps) for gait-assessment in normal pressure hydrocephalus and decompensated long-standing overt ventriculomegaly.
PubMed 文献 · Acta Neurochir (Wien) · 2024-09-28

研究开发了Watkins和Watkins2.0两款智能手机应用,用于执行10米步行测试(10MWT)和计时起立-行走测试(TUG)并记录结果。50名健康成人、67例正常压力脑积水(NPH)患者、10例失代偿性长期站立性巨脑室(LOVA)患者及5例老年跌倒风险评估患者使用Watkins2.0应用完成测试。应用与临床观察者秒表计时相比在时间测量上准确性高,在步数和距离测量上准确性稍低,并能区分健康人与步态障碍者。

要点

  • Watkins2.0应用在10MWT时间测量上准确性100%,步数准确性95%(误差±1-3步),距离准确性97%(误差±0.25-0.50米)。
  • TUG测试时间测量准确性100%,步数准确性97%(误差±1-2步),距离准确性87.5%(误差±0.50米)。
  • 应用在步数和距离测量中表现出高敏感性和精确性(AUC>0.9),并能显著区分健康与步态障碍个体。

核心结论

  • Watkins和Watkins2.0是用于NPH和LOVA患者客观执行10MWT和TUG测试的有效应用,并适用于其他以步态和平衡障碍为特征的情况。

研究设计与样本

  • 研究纳入50名健康成人、67例NPH患者、10例LOVA患者及5例老年跌倒风险评估患者,使用Watkins2.0应用执行10MWT(慢速和快速)和TUG测试,采用配对t检验比较健康与NPH队列,并用ROC曲线评估应用与临床观察者秒表计时的精确性。

主要发现

  • 与临床观察者秒表计时相比,10MWT中应用时间测量准确性100%,步数准确性95%(误差±1-3步),总距离准确性97%(误差±0.25-0.50米)。
  • TUG测试中应用时间测量准确性100%,步数准确性97%(误差±1-2步),距离准确性87.5%(误差±0.50米)。
  • 在时间测量上应用与观察者敏感性相同;在步数和距离测量上应用表现出高敏感性和精确性(AUC>0.9)。
  • 应用在健康与步态障碍个体间显示出显著区分能力。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Gait disturbance is one of the features of normal pressure hydrocephalus (NPH) and decompensated long-standing overt ventriculomegaly (LOVA). The timed-up-and-go (TUG) test and the timed-10-m-walking test (10MWT) are frequently used assessments tools for gait and balance disturbances in NPH and LOVA, as well as several other disorders. We aimed to make smart-phone apps which perform both the 10MWT and the TUG-test and record the results for individual patients, thus making it possible for patients to have an objective assessment of their progress. Patients with a suitable smart phone can perform repeat assessments in their home environment, providing a measure of progress for them and for their clinical team. METHODS: 10MWT and TUG-test were performed by 50 healthy adults, 67 NPH and 10 LOVA patients, as well as 5 elderly patients as part of falls risk assessment using the Watkins2.0 app. The 10MWT was assessed with timed slow-pace and fast-pace. Statistical analysis used SPSS (version 25.0, IBM) by paired t-test, comparing the healthy and the NPH cohorts. Level of precision of the app as compared to a clinical observer using a stopwatch was evaluated using receiver operating characteristics curve. RESULTS: As compared to a clinical observer using a stopwatch, in 10MWT the app showed 100% accuracy in the measure of time taken to cover distance in whole seconds, 95% accuracy in the number of steps taken with an error ± 1-3 steps, and 97% accuracy in the measure of total distance covered with error of ± 0.25-0.50 m. The TUG test has 100% accuracy in time taken to complete the test in whole seconds, 97% accuracy in the number of steps with an error of ± 1-2 steps and 87.5% accuracy in the distance covered with error of ± 0.50 m. In the measure of time, the app was found to have equal sensitivity as an observer. In measure of number of steps and distance, the app demonstrated high sensitivity and precision (AUC > 0.9). The app also showed significant level of discrimination between healthy and gait-impaired individuals. CONCLUSION: 'Watkins' and 'Watkins2.0' are efficient apps for objective performance of 10MWT and the TUG-test in NPH and LOVA patients and has application in several other pathologies characterised by gait and balance disturbance.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Tariq K, Thorne L, Toma A, et al. 'Watkins' & 'Watkins2.0': Smart phone applications (Apps) for gait-assessment in normal pressure hydrocephalus and decompensated long-standing overt ventriculomegaly. Acta Neurochir (Wien). 2024. PMID: 39333417. doi:10.1007/s00701-024-06275-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。