5-氨基乙酰丙酸引导的胶质瘤手术中术中共聚焦激光内镜:肿瘤边缘切除的重要考量
该研究在33例胶质瘤患者中同时使用荧光素钠共聚焦激光内镜(FNa CLE)与手术显微镜5-氨基乙酰丙酸(5-ALA)荧光成像,对88个深部和浅表边缘感兴趣区进行成像并与永久组织学切片比较。FNa CLE判断肿瘤边缘的敏感度和特异度分别为73%和41%,5-ALA分别为38%和82%;FNa CLE在检测浸润性肿瘤区域方面准确度高于术中5-ALA成像。
要点
- FNa CLE判断肿瘤边缘的敏感度73%、特异度41%,5-ALA分别为38%、82%。
- FNa CLE与永久组织学一致57/88(65%),5-ALA一致43/88(49%)。
- FNa CLE阳性预测值79%、阴性预测值33%,5-ALA分别为86%、31%。
核心结论
- 基于MRI和宽场荧光成像的常规术中肿瘤边缘评估可能低估胶质瘤的侵袭性。
- FNa CLE在检测浸润性肿瘤区域方面准确度高于术中5-ALA成像。
- 未来应考虑在更大患者队列中更严格地比较FNa CLE成像与5-ALA引导的切除。
研究设计与样本
- 研究纳入33例胶质瘤患者,使用FNa CLE与5-ALA宽场成像。
- CLE成像通过远程外科病理软件平台实时连接手术神经外科医生与远程病理学家。
- 对显微镜下主观认为的肿瘤边缘区域行FNa CLE成像后,在同一区域行5-ALA宽场成像并活检,与永久组织学切片比较。
主要发现
- 共对88个深部和浅表边缘感兴趣区(ROI)行FNa CLE和5-ALA成像。
- 神经病理学家根据FNa CLE判读为浸润性胶质瘤的大多数ROI缺乏5-ALA诱导荧光。
- 永久组织学切片与FNa CLE判读一致57/88(65%),与5-ALA判读一致43/88(49%)。
- FNa CLE判断肿瘤边缘的敏感度73%、特异度41%,5-ALA分别为38%、82%。
- CLE阳性预测值79%、阴性预测值33%,5-ALA分别为86%、31%。
局限性
- 原文结论提出未来应考虑在更大患者队列中更严格地比较FNa CLE成像与5-ALA引导的切除。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Because gliomas have poorly defined tumor margins, the ability to achieve maximal resection is limited. To better discern these margins, fluorescence-guided surgery has been used to aid maximal safe resection. The authors describe their experience with the simultaneous use of intraoperative fluorescein sodium (FNa) confocal laser endomicroscopy (CLE) and operating microscope 5-aminolevulinic acid (5-ALA) fluorescence imaging for glioma resection to improve CLE use for better margin discrimination. METHODS: FNa CLE and 5-ALA wide-field imaging were used in 33 patients with gliomas. CLE imaging was enhanced with the use of a telesurgical pathology software platform that enables real-time conversation between the operating neurosurgeons and the pathologists located remotely. CLE was used for imaging tumor regions that were subjectively regarded as tumor margins under normal visualization with the operative microscope. After FNa CLE imaging, 5-ALA wide-field imaging was performed in the same regions. Tissue was biopsied at imaging locations, and interpretations of FNa CLE and 5-ALA wide-field imaging were compared to those of permanent histological sections. RESULTS: Eighty-eight deep- and superficial-margin regions of interest (ROIs) were imaged with FNa CLE and 5-ALA imaging. Most of the ROIs interpreted by the neuropathologist as infiltrative glioma based on FNa CLE imaging lacked 5-ALA-induced fluorescence. Permanent histological sections from the corresponding regions were concordant with the interpretation of FNa CLE images in 57 of 88 (65%) ROIs and with the interpretation of 5-ALA imaging in 43 of 88 (49%) ROIs. The sensitivity and specificity of FNa CLE for the interpretation of tumor margins were 73% and 41%, respectively, and those of 5-ALA were 38% and 82%, respectively. Positive and negative predictive values for CLE were 79% and 33%, respectively, and those for 5-ALA were 86% and 31%, respectively. CONCLUSIONS: Conventional intraoperative evaluation of tumor margins, based on MRI and wide-field fluorescence imaging, can underestimate the invasiveness of gliomas. FNa CLE showed higher accuracy in detecting regions with infiltrating tumors than intraoperative 5-ALA imaging. Future considerations should include more rigorous comparisons of FNa CLE imaging and 5-ALA-guided resections on a larger cohort of patients.
引用
- Abramov I, Mathis AM, Xu Y, et al. Intraoperative confocal laser endomicroscopy during 5-aminolevulinic acid-guided glioma surgery: significant considerations for resection at the tumor margin. J Neurosurg. 2024. PMID: 39332037. doi:10.3171/2024.5.JNS24140
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。