高级别胶质瘤术后限制性弥散的生存影响及术中磁共振检测的局限性
回顾性分析165例使用3特斯拉术中磁共振的颅脑手术患者,比较术中与术后弥散加权成像。42例(25%)术后出现限制性弥散,其中37例(88%)术中磁共振未检出,假阴性率88%、敏感度12%。高级别胶质瘤中术后限制性弥散体积可预测总生存,独立于术后神经功能缺损(p=0.011)。
要点
- 高级别胶质瘤术后限制性弥散体积增大与中位总生存恶化相关,独立于术后神经功能缺损。
- 术中磁共振检测术后缺血性改变的敏感度为12%,假阴性率88%。
- 42例(25%)术后弥散加权成像显示至少部分限制性弥散,其中37例(88%)术中磁共振未检出。
核心结论
- 高级别胶质瘤中,术后限制性弥散体积增大与中位总生存恶化相关,且独立于术后神经功能缺损。
- 术中磁共振在评估术后缺血脑组织范围方面敏感度为12%、假阴性率为88%。
研究设计与样本
- 回顾性综述361例使用3特斯拉术中磁共振的颅脑手术,165例符合全部纳入标准并纳入最终分析。
- 将术中磁共振获得的弥散加权成像与术后7天内获得的弥散加权成像进行比较,仅纳入术中磁共振后未进一步切除的病例。
主要发现
- 165例中42例(25%)术后磁共振显示至少部分限制性弥散证据。
- 42例中37例(88%)术中磁共振缺乏限制性弥散证据,即术中磁共振假阴性率88%、敏感度12%。
- 高级别胶质瘤中,术后磁共振限制性弥散体积可预测总生存,独立于术中新增神经功能缺损(p=0.011)。
关键数值与推荐
- 165例中42例(25%)术后出现限制性弥散。
- 42例中37例(88%)术中磁共振未检出限制性弥散,假阴性率88%、敏感度12%。
- 高级别胶质瘤中术后限制性弥散体积预测总生存的p=0.011。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Here we assess whether the volume of cerebral ischemia induced during glioma surgery may negatively impact survival independently of neurological function. We also evaluate the sensitivity of intraoperative MRI (iMRI) in detecting cerebral ischemia during surgery. METHODS: We retrospectively reviewed 361 cranial surgeries that used a 3 Tesla iMRI. 165 patients met all inclusion criteria and were included in the final analysis. Diffusion weighted imaging (DWI) obtained during iMRI was compared to postoperative DWI obtained within 7 days of the operation in cases where no further resection occurred after the iMRI. RESULTS: 42 of 165 patients (25%) showed at least some evidence of restricted diffusion on postoperative (poMRI). 37 of these 42 (88%) cases lacked evidence of restricted diffusion on iMRI, meaning iMRI had a false-negative rate of 88% and a sensitivity of 12% in assessing the extent of ischemic brain after surgery. In high-grade gliomas, the volume of restricted diffusion on poMRI was predictive of overall survival, independent of new functional deficits acquired during surgery (p = 0.011). CONCLUSION: This study presents the largest case series to date analyzing the sensitivity of iMRI in detecting surgical ischemia. In high-grade gliomas, increased volume of ischemia correlated with worsening median overall survival (OS) irrespective of postoperative neurologic deficits. Future work will focus on improving intraoperative detection of ischemia during the hyperacute phase when interventions such as blood pressure modulation or direct application of vasodilator agents may be effective.
引用
- Aaronson DM, Laing B, Singhal I, et al. Survival implications of postoperative restricted diffusion in high-grade glioma and limitations of intraoperative MRI detection. J Neurooncol. 2024. PMID: 39316313. doi:10.1007/s11060-024-04767-3