全内镜下微血管减压术治疗三叉神经痛的标准操作流程与手术技术创新:189例技术报告
该回顾性临床分析纳入2019年6月至2022年8月接受全内镜下微血管减压术(EMVD)的原发性三叉神经痛(TN)患者189例,术者为双手操作、助手持镜。研究总结了EMVD标准操作流程,并开发针状双极电凝技术处理静脉压迫。随访期间178例(94.2%)疼痛缓解良好,4例(2.1%)疼痛复发;术后暂时性并发症包括三叉神经感觉异常7例(4.8%)、脑脊液漏2例(1.1%)、听力困难3例(1.6%)、面肌无力2例(1.1%)和眩晕5例(2.7%),无颅内出血、小脑肿胀和死亡病例。作者认为该EMVD技术可靠有效,可作为原发性TN的常规手术方式。
要点
- 189例原发性三叉神经痛患者接受全内镜下微血管减压术,术者双手操作、助手持镜。
- 随访中178例(94.2%)疼痛缓解良好,4例(2.1%)疼痛复发。
- 术后暂时性并发症包括三叉神经感觉异常7例(4.8%)、脑脊液漏2例(1.1%)等,无颅内出血、小脑肿胀和死亡。
核心结论
- 作者认为该全内镜下微血管减压术技术可靠有效,可作为原发性三叉神经痛的常规手术方式。
研究设计与样本
- 回顾性临床分析,纳入2019年6月至2022年8月接受全内镜下微血管减压术的原发性三叉神经痛患者189例。
- 术者为双手操作、助手持镜,通过分析术中情况、术后症状结局和主要并发症评估该技术的可靠性和有效性。
主要发现
- 随访期间178例(94.2%)疼痛缓解良好,4例(2.1%)疼痛复发。
- 术后暂时性并发症包括三叉神经感觉异常7例(4.8%)、脑脊液漏2例(1.1%)、听力困难3例(1.6%)、面肌无力2例(1.1%)和眩晕5例(2.7%)。
- 无颅内出血、小脑肿胀和死亡病例。
- 研究总结了术者双手操作、助手持镜的全内镜下微血管减压术标准操作流程,并开发针状双极电凝技术处理静脉压迫。
临床怎么用
- 作者认为该全内镜下微血管减压术技术可靠有效,可作为原发性三叉神经痛的常规手术方式。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Microvascular decompression (MVD) is a well-established and effective treatment for primary trigeminal neuralgia (TN). Endoscopy has been implemented to provide a comprehensive view of neurovascular conflict and minimizes the damages of brain retraction during MVD. OBJECTIVES: To preliminarily evaluate the surgical safety and efficacy of fully endoscopic microvascular decompression (EMVD) for primary TN with surgeon performing two-hand manipulation and assistant holding endoscope. METHODS: Retrospective clinical analysis of 189 patients with primary TN underwent EMVD between June 2019 and August 2022 was performed. By analyzing the intraoperative situation, the outcomes of postoperative symptoms and the main complications, we evaluated the reliability and effectivity of the operative technique in the treatment of primary TN. RESULTS: We summarized the standard operating procedure of EMVD for primary TN with surgeon performing two-hand manipulation and assistant holding endoscope. In addition, acicular bipolar electrocoagulation technique was developed to handle venous compression. During the follow-up period, good pain relief was achieved in 178 patients (94.2%) and recurrence of pain was observed in 4 patients (2.1%). Postoperative temporary complications included trigeminal dysesthesias (7 patients, 4.8%), cerebrospinal fluid leak (2 patients, 1.1%), hearing difficulty (3 patient, 1.6%), facial paresis (2 patients, 1.1%) and vertigo (5 patients, 2.7%). There were no cases of intracranial hemorrhage, cerebellar swelling and death. CONCLUSION: This EMVD technique is reliable and effective, and can be used as a routine surgical procedure for primary TN.
引用
- Guo X, Fu W, Zhang G, et al. Standard operating procedure and surgical technique innovation in fully endoscopic microvascular decompression for trigeminal neuralgia: technical note on 189 patients. Acta Neurochir (Wien). 2024. PMID: 39186137. doi:10.1007/s00701-024-06244-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。