文献速递功能神经外科

抗生素浸渍套囊降低脑深部电刺激脉冲发生器手术部位感染率:一项比较研究

Antibiotic-impregnated envelopes reduce the rate of surgical site infection in deep brain stimulation pulse generators: a comparative study.
PubMed 文献 · Acta Neurochir (Wien) · 2024-08-02

单中心回顾性分析2017年1月至2024年5月178例脑深部电刺激脉冲发生器置入或更换手术,2020年起常规使用抗生素浸渍套囊。使用套囊者感染率1.7%(58例中1例),未使用者5%(120例中6例),无套囊时感染比值比为2.9倍,并节省费用。

要点

  • 使用抗生素浸渍套囊者脉冲发生器感染率1.7%(58例中1例),未使用者5%(120例中6例)。
  • 无套囊时感染比值比为使用套囊的2.9倍。
  • 感染率下降见于初次置入和更换手术,超过80%的感染患者需外科干预。

核心结论

  • 使用抗生素浸渍套囊可降低脑深部电刺激脉冲发生器相关感染的发生率,初次置入和更换手术中均可见此效果,并带来经济收益。

研究设计与样本

  • 单中心回顾性分析,纳入2017年1月至2024年5月所有脉冲发生器置入和更换手术,共178例患者,2020年起常规使用抗生素浸渍套囊。

主要发现

  • 使用抗生素浸渍套囊者脉冲发生器手术部位感染率为1.7%(58例中1例,其中初次置入20例、更换38例),未使用者为5%(120例中6例,其中初次置入36例、更换84例)。
  • 无抗生素浸渍套囊时感染比值比为使用套囊的2.9倍。
  • 感染率下降在初次置入和更换脉冲发生器手术中均观察到。
  • 超过80%的脉冲发生器感染患者需要外科干预。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: Deep brain stimulation (DBS) is a surgical procedure that has been used to treat a variety of neurological disorders including Parkinson's disease, essential tremor, and dystonia. While DBS is generally considered safe and effective, surgical site infections (SSIs) are a potential complication that can lead to significant morbidity and mortality. Our objective was to investigate the use of antibiotic-impregnated envelopes (AIEs) encasing implantable pulse generators (IPGs) to reduce the rate of infection at IPG sites and the costs. METHODS: We conducted a retrospective analysis at a single center encompassing all procedures involving the placement of Implantable Pulse Generators (IPG), including both initial insertions and replacement surgeries. The study period spanned from January 2017 to May 2024. Starting in 2020, the routine utilization of AIE became standard practice at our institute for both primary DBS implantation and IPG replacements. Surgical techniques remained consistent, pre- and post-operative antibiotic protocols were standardized throughout the study period and all cases were undertaken by a single surgeon. RESULTS: 178 patients were included and the overall incidence of IPG SSIs was found to be 1.7% (1 infection in 58 patients; 20 primary IPG/38 IPG replacements) among those who received an AIE compared to 5% (6 infections in 120 patients; 36 primary IPG/84 replacement IPG) in patients where no AIE was utilized. This resulted in an odds ratio for infection that was 2.9 times higher in the absence of AIE. The decrease in infection rates was observed in both primary and replacement IPG implants. Notably, over 80% of patients with IPG infection required surgical intervention. The use of AIE further resulted in significant cost savings. CONCLUSION: To our knowledge, this is the largest series reporting the efficacy of Antibiotic impregnated envelope (AIE) in modifying infection rates associated with both initial and replacement Deep Brain Stimulation (DBS) Implantable Pulse Generators (IPGs). The implementation of AIEs led to a decrease in the occurrence of IPG-related infections, observed across both primary implantations and replacement surgeries, with associated economic benefits.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Raslan A, Alkhafaji NY, Mostofi A, et al. Antibiotic-impregnated envelopes reduce the rate of surgical site infection in deep brain stimulation pulse generators: a comparative study. Acta Neurochir (Wien). 2024. PMID: 39090257. doi:10.1007/s00701-024-06200-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。