复发高级别胶质瘤术中5-氨基乙酰丙酸光动力诊断联合他拉泊芬钠光动力治疗的安全性
本研究纳入7例复发高级别胶质瘤患者,术中行5-氨基乙酰丙酸光动力诊断联合他拉泊芬钠光动力治疗,评估光敏性等不良事件。仅1例(14.3%)发生光敏反应,3例出现CTCAE 1或2级肝功能异常,1例出现CTCAE 1级γ-GTP升高,均随访改善。作者认为联合使用未增加严重不良事件风险,但需更大样本进一步研究。
要点
- 7例复发高级别胶质瘤行5-ALA-PDD联合TS-PDT,光敏反应仅1例(14.3%)。
- 3例出现CTCAE 1或2级肝功能异常,1例CTCAE 1级γ-GTP升高,均随访改善。
- 作者认为联合使用未增加严重不良事件风险,需更大样本进一步研究。
核心结论
- 作者认为,在本研究中5-ALA-PDD联合TS-PDT用于高级别胶质瘤手术未增加严重不良事件风险。
- 作者指出需更大样本量的进一步研究以更准确评估其安全性和有效性。
研究设计与样本
- 本研究为7例复发高级别胶质瘤患者接受5-ALA-PDD联合TS-PDT肿瘤切除术的安全性报告。
- 按药品说明书评估5-ALA和TS相关光敏性不良反应,不良事件依据CTCAE 5.0版评估。
主要发现
- 肿瘤特异性荧光强度:4例强,3例弱。
- 光敏反应仅发生于1例患者(14.3%)。
- 3例出现CTCAE 1或2级肝功能异常,1例出现CTCAE 1级γ-GTP升高,所有异常均在随访期间改善。
局限性
- 原文指出需更大样本量的进一步研究以更准确评估其安全性和有效性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Intraoperative photodynamic diagnosis (PDD) using 5-aminolevulinic acid (5-ALA) is a widely adopted technique to enhance the extent of resection during high-grade glioma (HGG) surgery. Recent updates to the package insert for 5-ALA in Japan now allow its use in combination with drugs that may induce photosensitivity, such as talaporfin sodium (TS). TS is employed in intraoperative photodynamic therapy (PDT) and has been shown to improve overall survival. The combination of 5-ALA with TS is expected to offer further benefits. However, the safety of this combination had not been established. This study reports on the safety of 5-ALA-PDD with TS-PDT in the treatment of recurrent HGG. METHODS: 7 patients with recurrent HGG underwent tumor resection using a combination of 5-ALA-PDD and TS-PDT. The incidence of photosensitivity as an adverse effect associated with 5-ALA and TS was evaluated as described in the package insert. Adverse events were assessed according to the Common Terminology Criteria for Adverse Events (CTCAE) version 5.0. RESULTS: Tumor-specific fluorescence intensity was strong in 4 cases and weak in 3. Photosensitivity occurred in only 1 patient (14.3%). Three patients exhibited CTCAE grade 1 or 2 abnormal liver function, and 1 patient experienced CTCAE grade 1 γ-GTP elevation. All abnormalities improved during follow-up. CONCLUSIONS: The combined use of 5-ALA-PDD and TS-PDT for HGG surgery did not increase the risk of serious adverse events in our study. Further investigations with a larger number of cases are needed for a more accurate assessment of its safety and efficacy.
引用
- Kohzuki H, Miki S, Sugii N, et al. The Safety of Intraoperative Photodynamic Diagnosis Using 5-Aminolevulinic Acid Combined with Talaporfin Sodium Photodynamic Therapy in Recurrent High-Grade Glioma. World Neurosurg. 2024. PMID: 39116940. doi:10.1016/j.wneu.2024.07.211
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。