文献速递神经重症小儿神经外科与脑积水

超声测量视神经鞘直径诊断儿童颅内压升高的准确性:系统评价与Meta分析

Diagnostic Accuracy of Optic Nerve Sheath Diameter Using Ultrasonography for Raised Intracranial Pressure in Pediatric Patients - A Systematic Review and Meta-Analysis.
PubMed 文献 · World Neurosurg · 2024-08-12

该系统评价与Meta分析检索四个数据库,纳入25项诊断准确性研究共1591例患儿、3143次超声视神经鞘直径测量,评估其预测颅内压升高的准确性。汇总敏感度为92%(86%-96%),特异度为89%(77%-96%),阳性似然比8.6,阴性似然比0.08。作者推荐对儿科患者常规行眼部超声测量视神经鞘直径以提高颅内压升高诊断准确性。

要点

  • 超声测量视神经鞘直径预测儿童颅内压升高,汇总敏感度92%(86%-96%)、特异度89%(77%-96%)。
  • 汇总阳性似然比8.6,阴性似然比0.08。
  • 作者推荐对儿科患者常规行眼部超声测量视神经鞘直径。

核心结论

  • 眼部超声测量视神经鞘直径是适用于不同患者人群和临床场景的精确且有价值的诊断工具。
  • 作者推荐对儿科患者常规行眼部超声测量视神经鞘直径以提高颅内压升高诊断准确性。

研究设计与样本

  • 系统评价与Meta分析,检索PubMed、EMBASE、Scopus和CINAHL四个数据库。
  • 纳入诊断准确性、横断面、前瞻性观察性和回顾性研究,对象为创伤性脑损伤和脑水肿等原因所致颅内压升高的儿童。
  • 共纳入25项研究,1591例患者,3143次超声视神经鞘直径测量。
  • 以有创监测(脑室外引流)和非侵入性措施作为颅内压升高的金标准。
  • 由两名作者提取并审核数据,提取基线数据、结局指标和诊断准确性数据。

主要发现

  • 超声测量视神经鞘直径预测颅内压升高的汇总敏感度为92%(86%-96%),汇总特异度为89%(77%-96%)。
  • 汇总阳性似然比为8.6,阴性似然比为0.08。

临床怎么用

  • 作者推荐对儿科患者常规行眼部超声测量视神经鞘直径以提高颅内压升高诊断准确性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Detecting increased intracranial pressure early in pediatric patients is essential, as early initiation of therapy prevents morbidity and mortality. The objective of this study was to determine the diagnostic accuracy of the optic nerve sheath diameter (ONSD) measured via ultrasound for the prediction of increased intracranial pressure. METHODS: Four databases, namely, PubMed, EMBASE, Scopus, and CINAHL, were searched for this systematic review and meta-analysis. The study's predefined inclusion criteria considered diagnostic accuracy, cross-sectional, prospective observational, and retrospective studies with a focus on children with elevated intracranial pressure from causes such as traumatic brain injury and cerebral edema, the diagnostic accuracy of the optic nerve sheath diameter measured using ultrasound was assessed. The primary outcome measures included sensitivity and specificity. The study included invasive monitoring (external ventricular drain) and noninvasive measures as the gold standards for increased intracranial pressure. Two authors extracted and reviewed the data. Baseline data, outcome measures, and diagnostic accuracy data were extracted. RESULTS: Twenty-five studies with 1591 patients and 3143 ONSD measurements via ultrasound were analyzed. The pooled sensitivity and specificity of the ONSD measured via ultrasound for the prediction of increased intracranial pressure were 92% (86%-96%) and 89% (77%-96%), respectively. The pooled positive and negative likelihood ratios were 8.6 and 0.08, respectively. CONCLUSION AND RELEVANCE: Optic nerve ultrasonography stands out as a precise and valuable diagnostic tool applicable across diverse patient populations and clinical scenarios. We recommend routine ocular ultrasound for optic nerve sheath diameter measurement in pediatric patients to increase the accuracy of diagnosing increased intracranial pressure.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Rajendran G, Mahalingam S, Ramkumar A, et al. Diagnostic Accuracy of Optic Nerve Sheath Diameter Using Ultrasonography for Raised Intracranial Pressure in Pediatric Patients - A Systematic Review and Meta-Analysis. World Neurosurg. 2024. PMID: 39142382. doi:10.1016/j.wneu.2024.08.052

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。