文献速递神经创伤神经重症

超声评估视神经鞘直径作为创伤性脑损伤颅内高压筛查工具

Ultrasonographic Assessment of Optic Nerve Sheath Diameter as a Screening Tool for Intracranial Hypertension in Traumatic Brain Injury.
PubMed 文献 · World Neurosurg · 2024-08-27

该研究在置入脑实质内传感器的重型闭合性颅脑损伤患者队列中,分析超声测量的视神经鞘直径(ONSD)随颅内压(ICP)变化的情况,评估ONSD区分二分ICP阈值的准确性,并分析其学习曲线及作为筛查工具在资源受限环境中筛选最需有创ICP监测的TBI患者的潜力。结果显示ONSD与ICP呈线性关系,存在一对一对应评估的局限;作者选定超声ONSD阈值以提示ICP>15 mmHg值得有创二线监测。

要点

  • ONSD与ICP呈线性关系,但存在评估两者一对一对应的局限。
  • 作者选定超声ONSD阈值以提示ICP>15 mmHg值得有创二线监测。
  • 作者提出在急诊科将ONSD超声作为创伤后颅内高压的筛查检查,尤其ICP监测仪可用性有限的环境。

核心结论

  • 作者提出在急诊科将ONSD超声作为创伤后颅内高压的筛查检查,尤其ICP监测仪可用性有限的环境。

研究设计与样本

  • 在置入脑实质内传感器的重型闭合性颅脑损伤患者队列中,研究超声测量的ONSD随ICP变化的情况,评估ONSD区分二分ICP阈值的准确性,并分析其学习曲线及作为筛查工具在资源受限环境中筛选最需有创ICP监测的TBI患者的潜力。

主要发现

  • ONSD与ICP呈线性关系,但存在评估两者一对一对应的局限。
  • 作者选定超声ONSD阈值以提示ICP>15 mmHg值得有创二线监测。
  • 因此,可能将ONSD作为一线无创工具来拦截有发生明显颅内高压风险的患者。

关键数值与推荐

  • 作者选定超声ONSD阈值以提示ICP>15 mmHg值得有创二线监测。

临床怎么用

  • 作者提出在急诊科将ONSD超声作为创伤后颅内高压的筛查检查,尤其ICP监测仪可用性有限的环境。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Severe traumatic brain injury (TBI) is a condition burdened by high morbidity and mortality. Prevention of secondary insults is 1 of the main goals of management and intracranial pressure (ICP) monitoring is a cornerstone in management of TBI. The relationship between ICP and optic nerve sheath is known from the literature. Optic nerve sheath ultrasonography could represent a method added to our armamentarium for monitoring ICP. METHODS: We investigated how ultrasound-measured optic nerve sheath diameter (ONSD) varies as a function of ICP in a cohort of patients with severe blunt head injury in whom an intraparenchymal sensor was placed. We evaluated the accuracy of ONSD in distinguishing dichotomized ICP cut-offs and analyzed the learning curve and its potential as screening tool to select TBI patients most in need of invasive ICP monitoring in a setting with constraints on resources. RESULTS: ONSD and ICP have a linear relationship. Nevertheless, there are limits of evaluating the one-to-one correspondence between those 2 variables. We selected a cut-off of sonographic ONSD above which there is a concernable elevation of ICP (ICP >15 mmHg) worthy of invasive second-line monitoring. Thus, it is possible to use ONSD as a first-line noninvasive tool to intercept patients at risk of developing frank intracranial hypertension. CONCLUSIONS: We propose the use of ONSD ultrasound as a screening investigation for post-traumatic intracranial hypertension in the context of an emergency department, especially in contexts where there is limited availability of ICP monitors.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Lioi F, Ramm-Pettersen J, Fratini A, et al. Ultrasonographic Assessment of Optic Nerve Sheath Diameter as a Screening Tool for Intracranial Hypertension in Traumatic Brain Injury. World Neurosurg. 2024. PMID: 39209251. doi:10.1016/j.wneu.2024.08.111