腰椎术后椎弓根螺钉松动预测性能比较:基于CT的Hounsfield单位与基于MRI的椎体骨质量评分
回顾性研究纳入2018年5月至2020年9月连续接受经椎间孔腰椎椎间融合术的患者,比较基于CT的Hounsfield单位(HU)与基于MRI的椎体骨质量评分(VBQ)对椎弓根螺钉松动的预测性能。结果显示两者总体预测性能无显著差异(PAUC=0.076),但在腰椎管狭窄患者中VBQ评分预测能力显著优于HU值(PAUC=0.003)。
要点
- VBQ评分与CT HU值预测螺钉松动的总体AUC分别为0.752与0.652,差异无统计学意义(PAUC=0.076)。
- 腰椎管狭窄患者中VBQ评分AUC为0.863,显著高于HU值的0.673(PAUC=0.003)。
- 螺钉松动定义为随访12个月X线片显示螺钉周围最小厚度≥1 mm的透亮带。
核心结论
- 基于MRI的VBQ评分与基于CT的HU值在预测腰椎术后椎弓根螺钉松动方面性能相似。
- 在腰椎管狭窄患者中,VBQ评分显示出比HU值更好的预测能力。
研究设计与样本
- 回顾性研究,连续纳入2018年5月至2020年9月在本机构接受经椎间孔腰椎椎间融合术的患者。
- 基于12个月随访的腰椎X线片定义螺钉松动为螺钉周围最小厚度≥1 mm的透亮带。
- VBQ评分和HU值分别通过术前MRI和CT测量,采用受试者工作特征曲线比较预测性能。
主要发现
- 全部患者中,VBQ评分的曲线下面积(AUC=0.752;95%CI 0.663-0.841;P<0.001)大于CT HU值的AUC(0.652;95%CI 0.558-0.746;P=0.005),但两者差异无统计学意义(PAUC=0.076)。
- 腰椎管狭窄患者中,VBQ评分的AUC(0.863;95%CI 0.764-0.961;P<0.001)大于CT HU值的AUC(0.673;95%CI 0.513-0.833;P=0.043),差异有统计学意义(PAUC=0.003)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To compare predictive performance for pedicle screw loosening between computed tomography (CT)-based Hounsfield units (HU) and magnetic resonance imaging (MRI)-based vertebral bone quality score (VBQ) after lumbar surgery. METHODS: A retrospective study was conducted on patients who received transforaminal lumbar interbody fusion continuously at our institution from May 2018 to September 2020. On the basis of 12 months' follow-up lumbar radiographs, screw loosening was defined as a clear zone of minimal thickness of ≥1 mm around the pedicle screw on radiography. VBQ score and HU value were measured using preoperative MRI and CT, respectively. Then, we evaluated the predictive performance of these 2 parameters by comparing the receiver operating characteristic curve. RESULTS: In all patients, area under the curve (AUC) of the VBQ score (AUC = 0.752; 95% confidence interval [CI] 0.663-0.841; P < 0.001) was larger than those of the CT HU value (AUC = 0.652; 95% CI 0.558-0.746; P = 0.005), but there was no significant difference between them (PAUC = 0.076). In patients with lumbar spinal stenosis, AUC of VBQ score (AUC = 0.863; 95% CI 0.764-0.961; P < 0.001) was larger than those of the CT HU value (AUC = 0.673; 95% CI 0.513-0.833; P = 0.043), with significant difference (PAUC = 0.003). CONCLUSIONS: MRI-based VBQ score and CT-based HU value have similar performance in predicting pedicle screw loosening after lumbar surgery. Furthermore, in patients with lumbar spinal stenosis, VBQ score demonstrated better predictive ability than HU value.
引用
- Ye W, Wang J, Wang X, et al. Comparison of Predictive Performance for Pedicle Screw Loosening Between Computed Tomography-Based Hounsfield Units and Magnetic Resonance Imaging-Based Vertebral Bone Quality Score After Lumbar Surgery. World Neurosurg. 2024. PMID: 39032631. doi:10.1016/j.wneu.2024.07.088
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。