扩散MRI衍生的脊髓指标在颈椎脊髓型颈椎病预后判断中优于传统MRI
研究纳入47例颈椎脊髓型颈椎病(CSM)患者和21名对照,比较传统MRI、弥散张量成像(DTI)和扩散基谱成像(DBSI)在疾病分类和2年手术预后判断中的准确性。DBSI模型分类准确率为0.81(95%CI 0.808-0.814),预后判断准确率为0.72(95%CI 0.718-0.73),均高于传统MRI(分类0.647,预后0.58)和DTI(分类0.52,预后0.62)。
要点
- DBSI分类准确率0.81,高于传统MRI的0.647和DTI的0.52。
- DBSI预后判断准确率0.72,高于传统MRI的0.58和DTI的0.62。
- 传统MRI在表征脊髓组织损伤方面存在固有局限。
核心结论
- DBSI衍生指标可提供脊髓微结构的精细评估,具有更好的诊断和预后判断效用。
研究设计与样本
- 47例CSM患者和21名对照受试者接受全面临床评估和扩散MRI(dMRI),并进行DTI和DBSI建模。
- 主要结局为术后2年测量的改良日本骨科协会(mJOA)评分。
- 采用极端梯度提升监督分类算法对患者进行疾病分组和2年随访手术预后判断。
主要发现
- 47例CSM患者中,mJOA评分轻度24例(51%)、中度12例(26%)、重度11例(23%)。
- 分类任务中,传统MRI指标准确率为0.647(95%CI 0.64-0.65),DTI模型为0.52(95%CI 0.51-0.52),DBSI模型为0.81(95%CI 0.808-0.814)。
- 预后判断任务中,传统MRI指标准确率为0.58(95%CI 0.57-0.58),DTI模型为0.62(95%CI 0.61-0.62),DBSI模型为0.72(95%CI 0.718-0.73)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: A major shortcoming in optimizing care for patients with cervical spondylotic myelopathy (CSM) is the lack of robust quantitative imaging tools offered by conventional MRI. Advanced MRI modalities, such as diffusion MRI (dMRI), including diffusion tensor imaging (DTI) and diffusion basis spectrum imaging (DBSI), may help address this limitation by providing granular evaluations of spinal cord microstructure. METHODS: Forty-seven patients with CSM underwent comprehensive clinical assessments and dMRI, followed by DTI and DBSI modeling. Conventional MRI metrics included 10 total qualitative and quantitative assessments of spinal cord compression in both the sagittal and axial planes. The dMRI metrics included 12 unique measures including anisotropic tensors, reflecting axonal diffusion, and isotropic tensors, describing extraaxonal diffusion. The primary outcome was the modified Japanese Orthopaedic Association (mJOA) score measured at 2 years postoperatively. Extreme gradient boosting-supervised classification algorithms were used to classify patients into disease groups and to prognosticate surgical outcomes at 2-year follow-up. RESULTS: Forty-seven patients with CSM, including 24 (51%) with a mild mJOA score, 12 (26%) with a moderate mJOA score, and 11 (23%) with a severe mJOA score, as well as 21 control subjects were included. In the classification task, the traditional MRI metrics correctly assigned patients to healthy control versus mild CSM versus moderate/severe CSM cohorts, with an accuracy of 0.647 (95% CI 0.64-0.65). In comparison, the DTI model performed with an accuracy of 0.52 (95% CI 0.51-0.52) and the DBSI model's accuracy was 0.81 (95% CI 0.808-0.814). In the prognostication task, the traditional MRI metrics correctly predicted patients with CSM who improved at 2-year follow-up on the basis of change in mJOA, with an accuracy of 0.58 (95% CI 0.57-0.58). In comparison, the DTI model performed with an accuracy of 0.62 (95% CI 0.61-0.62) and the DBSI model had an accuracy of 0.72 (95% CI 0.718-0.73). CONCLUSIONS: Conventional MRI is a powerful tool to assess structural abnormality in CSM but is inherently limited in its ability to characterize spinal cord tissue injury. The results of this study demonstrate that advanced imaging techniques, namely DBSI-derived metrics from dMRI, provide granular assessments of spinal cord microstructure that can offer better diagnostic and prognostic utility.
引用
- Zhang JK, Yakdan S, Kaleem MI, et al. Spinal cord metrics derived from diffusion MRI: improvement in prognostication in cervical spondylotic myelopathy compared with conventional MRI. J Neurosurg Spine. 2024. PMID: 39059420. doi:10.3171/2024.4.SPINE24107
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。