文献速递神经肿瘤

5T谷氨酸化学交换饱和转移成像在脑肿瘤中的应用:初步结果

Application of 5T glutamate chemical exchange saturation transfer imaging in brain tumors: preliminary results.
PubMed 文献 · J Neurooncol · 2024-07-03

研究在10名健康志愿者中评估5T谷氨酸化学交换饱和转移(GluCEST)成像的可重复性,并对28例脑肿瘤患者术前扫描,比较不同肿瘤的GluCEST值。结果显示健康志愿者GluCEST值变异系数在个体内低于5%、个体间低于10%;高级别胶质瘤GluCEST值高于低级别胶质瘤(P<0.001),桥小脑角脑膜瘤高于听神经瘤(P<0.001),鉴别两者的曲线下面积为0.93。

要点

  • 5T GluCEST在健康脑中可重复性高,个体内变异系数<5%,个体间<10%。
  • 高级别胶质瘤GluCEST值高于低级别胶质瘤(P<0.001)。
  • 桥小脑角脑膜瘤GluCEST值高于听神经瘤(P<0.001),AUC为0.93。

核心结论

  • 5T GluCEST图像在健康脑中具有高可重复性,并在鉴别低级别与高级别胶质瘤、桥小脑角脑膜瘤与听神经瘤方面具有潜在临床应用价值。

研究设计与样本

  • 10名健康志愿者(4名男性,平均年龄29岁)接受三次5T GluCEST成像扫描,采用单因素重复测量方差分析、广义估计方程和线性混合模型评估可重复性。
  • 28例脑肿瘤患者(10名男性,平均年龄54岁)术前接受单次GluCEST扫描,采用t检验比较不同脑肿瘤间GluCEST值差异,并用受试者工作特征(ROC)曲线评估诊断准确性。

主要发现

  • 健康志愿者GluCEST值的变异系数在日内、日间和个体内均小于5%,个体间小于10%。
  • 高级别胶质瘤(HGG)的GluCEST值高于低级别胶质瘤(LGG)(P < 0.001)。
  • 桥小脑角(CPA)脑膜瘤的GluCEST值高于听神经瘤(P < 0.001)。
  • GluCEST值鉴别CPA脑膜瘤与听神经瘤的曲线下面积(AUC)为0.93。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Glutamate chemical exchange saturation transfer (GluCEST) is a non-invasive CEST imaging technique for detecting glutamate levels in tissues. We aimed to investigate the reproducibility of the 5T GluCEST technique in healthy volunteers and preliminarily explore its potential clinical application in patients with brain tumors. METHODS: Ten volunteers (4 males, mean age 29 years) underwent three 5T GluCEST imaging scans. The reproducibility of the three imaging GluCEST measurements was assessed using one-way repeated measures analysis of variance (ANOVA), generalized estimating equations, and linear mixed models. Twenty-eight patients with brain tumors (10 males, mean age 54 years) underwent a single GluCEST scan preoperatively, and t-tests were used to compare the differences in GluCEST values between different brain tumors. In addition, the diagnostic accuracy of GluCEST values in differentiating brain tumors was assessed using the receiver work characteristics (ROC) curve. RESULTS: The coefficients of variation of GluCEST values in healthy volunteers were less than 5% for intra-day, inter-day, and within-subjects and less than 10% for between-subjects. High-grade gliomas (HGG) had higher GluCEST values compared to low-grade gliomas (LGG) (P < 0.001). In addition, cerebellopontine angle (CPA) meningiomas had higher GluCEST values than acoustic neuromas (P < 0.001). The area under the curve (AUC) of the GluCEST value for differentiating CPA meningioma from acoustic neuroma was 0.93. CONCLUSION: 5T GluCEST images are highly reproducible in healthy brains. In addition, the 5T GluCEST technique has potential clinical applications in differentiating LGG from HGG and CPA meningiomas from acoustic neuromas.

来源:J Neurooncol,查看原文。版权归原作者所有。

引用

  1. Zhou J, Sun W, Li H, et al. Application of 5T glutamate chemical exchange saturation transfer imaging in brain tumors: preliminary results. J Neurooncol. 2024. PMID: 38958848. doi:10.1007/s11060-024-04759-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。