利用对比率作为定量磁共振成像方法鉴别硬膜内髓外脊柱肿瘤中的神经鞘瘤与脑膜瘤
本研究分析50例经手术及组织病理学诊断为神经鞘瘤或脑膜瘤的硬膜内髓外脊柱肿瘤患者,在T2加权矢状位MRI上计算肿瘤对比率(CR)。神经鞘瘤平均CR为0.3040±0.1386,脑膜瘤为0.0173±0.1929,前者显著高于后者(P<0.01);ROC曲线最佳截断值0.143,特异度90.9%、敏感度88.2%,曲线下面积0.925(95%CI 0.852-0.998)。作者认为MRI对比率评估是鉴别二者的有益定量工具。
要点
- 神经鞘瘤平均CR为0.3040±0.1386,脑膜瘤为0.0173±0.1929(P<0.01)。
- CR截断值0.143,特异度90.9%、敏感度88.2%。
- ROC曲线下面积0.925(95%CI 0.852-0.998)。
核心结论
- 利用MRI评估对比率来鉴别神经鞘瘤与脑膜瘤是一种有益的定量工具。
研究设计与样本
- 回顾性分析经手术及组织病理学诊断为神经鞘瘤或脑膜瘤的硬膜内髓外脊柱肿瘤患者数据,共50例(男23例、女27例),平均年龄61.5岁(范围11-85岁)。
- 在T2加权矢状位MRI上对整个脊柱肿瘤设置感兴趣区,按公式CRtumor=(SItumor-SIcord)/(SItumor+SIcord)计算肿瘤对比率。
主要发现
- 组织病理学诊断神经鞘瘤33例、脑膜瘤17例。
- 神经鞘瘤平均CR为0.3040±0.1386,脑膜瘤为0.0173±0.1929,神经鞘瘤显著高于脑膜瘤(P<0.01)。
- ROC曲线获得的CR截断值为0.143,特异度90.9%、敏感度88.2%。
- ROC曲线下面积为0.925(95%CI 0.852-0.998)。
关键数值与推荐
- CR截断值0.143,特异度90.9%、敏感度88.2%。
- ROC曲线下面积0.925(95%CI 0.852-0.998)。
临床怎么用
- 作者认为利用MRI评估对比率来鉴别神经鞘瘤与脑膜瘤是一种有益的定量工具。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Schwannomas and meningiomas are the most common intradural extramedullary spinal tumors; however, differentiating between them using magnetic resonance imaging (MRI) is a frequent challenge. In this study, we aimed to investigate the use of the contrast ratio (CR) as a quantitative MRI method in the differentiation of schwannomas and meningiomas. METHODS: We analyzed the data of patients with intradural extramedullary spinal tumors who underwent surgery and were diagnosed with either schwannomas or meningiomas by histopathological analysis. Regions of interest were set for the entire spinal tumor on T2-weighted sagittal MRI. To obtain the CR values of spinal tumors (CRtumor), we used the signal intensity (SI) values of the tumor (SItumor) and spinal cord (SIcord) according to the following formula: [CRtumor = (SItumor-SIcord)/(SItumor+SIcord)]. RESULTS: The study included 50 patients (23 males and 27 females) with a mean age of 61.5 years old (11-85 years old). Histopathological analysis revealed that 33 and 17 patients were diagnosed with schwannomas and meningiomas, respectively. The mean CR values of the schwannomas and meningiomas were 0.3040 ± 0.1386 and 0.0173 ± 0.1929, respectively. The CR value of the schwannomas was statistically significantly higher than that of meningiomas (P < 0.01). The cutoff CR value obtained from the receiver operating characteristic curve was 0.143, with a specificity and sensitivity of 90.9% and 88.2%, respectively. Furthermore, the value for the area under the receiver operating characteristic curve was 0.925 (95% confidence interval: 0.852-0.998). CONCLUSIONS: The evaluation of CRs by using MRI to distinguish between schwannomas and meningiomas is a beneficial quantitative tool.
引用
- Nakamae T, Kamei N, Tamura T, et al. Differentiation of the Intradural Extramedullary Spinal Tumors, Schwannomas, and Meningiomas Utilizing the Contrast Ratio as a Quantitative Magnetic Resonance Imaging Method. World Neurosurg. 2024. PMID: 38797281. doi:10.1016/j.wneu.2024.05.106
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。