文献速递神经肿瘤

基于超声吸引器标本的儿童脑肿瘤快速DNA甲基化分类

Rapid DNA methylation-based classification of pediatric brain tumors from ultrasonic aspirate specimens.
PubMed 文献 · J Neurooncol · 2024-05-21

本研究探索利用超声吸引器切除、原本丢弃的肿瘤组织,通过低通量纳米孔全基因组测序进行快速DNA甲基化分类的可行性。19例有神经病理诊断的儿童脑肿瘤标本全部成功测序,甲基化分类与EPIC芯片结果一致17/19(89%),拷贝数变异谱一致18/19(95%);采用平台特异性阈值后特异性100%、敏感性79%。结论认为基于超声吸引器来源丢弃组织的甲基化分类是可行的。

要点

  • 超声吸引器来源的儿童脑肿瘤组织可成功完成低通量纳米孔测序并通过质控。
  • 甲基化分类与常规EPIC芯片结果一致17/19(89%),拷贝数变异谱一致18/19(95%)。
  • 采用平台特异性阈值后纳米孔分类特异性100%、敏感性79%。

核心结论

  • 基于超声吸引器切除、原本丢弃的儿童中枢神经系统肿瘤组织,利用省时经济的纳米孔测序进行甲基化分类是可行的。

研究设计与样本

  • 前瞻性收集接受脑肿瘤切除术的儿童患者超声吸引器来源标本,行低通量纳米孔全基因组测序,并以神经网络分类器进行DNA甲基化分类及拷贝数变异分析,结果与常规EPIC芯片神经病理组织形态学和分子评估比较。

主要发现

  • 19例有确认神经病理诊断的标本全部成功测序并通过质控,其DNA及测序特征与常规处理肿瘤组织相当。
  • 两种方法甲基化分类一致17/19(89%)。
  • 采用平台特异性阈值后,纳米孔分类特异性100%、敏感性79%。
  • 所有病例均生成拷贝数变异谱,与EPIC结果一致18/19(95%),并可识别诊断或治疗相关的基因组改变。

关键数值与推荐

  • 甲基化分类一致率17/19(89%)。
  • 拷贝数变异谱与EPIC一致18/19(95%)。
  • 平台特异性阈值下纳米孔分类特异性100%、敏感性79%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Although cavitating ultrasonic aspirators are commonly used in neurosurgical procedures, the suitability of ultrasonic aspirator-derived tumor material for diagnostic procedures is still controversial. Here, we explore the feasibility of using ultrasonic aspirator-resected tumor tissue to classify otherwise discarded sample material by fast DNA methylation-based analysis using low pass nanopore whole genome sequencing. METHODS: Ultrasonic aspirator-derived specimens from pediatric patients undergoing brain tumor resection were subjected to low-pass nanopore whole genome sequencing. DNA methylation-based classification using a neural network classifier and copy number variation analysis were performed. Tumor purity was estimated from copy number profiles. Results were compared to microarray (EPIC)-based routine neuropathological histomorphological and molecular evaluation. RESULTS: 19 samples with confirmed neuropathological diagnosis were evaluated. All samples were successfully sequenced and passed quality control for further analysis. DNA and sequencing characteristics from ultrasonic aspirator-derived specimens were comparable to routinely processed tumor tissue. Classification of both methods was concordant regarding methylation class in 17/19 (89%) cases. Application of a platform-specific threshold for nanopore-based classification ensured a specificity of 100%, whereas sensitivity was 79%. Copy number variation profiles were generated for all cases and matched EPIC results in 18/19 (95%) samples, even allowing the identification of diagnostically or therapeutically relevant genomic alterations. CONCLUSION: Methylation-based classification of pediatric CNS tumors based on ultrasonic aspirator-reduced and otherwise discarded tissue is feasible using time- and cost-efficient nanopore sequencing.

来源:J Neurooncol,查看原文。版权归原作者所有。

引用

  1. Simon M, Kuschel LP, von Hoff K, et al. Rapid DNA methylation-based classification of pediatric brain tumors from ultrasonic aspirate specimens. J Neurooncol. 2024. PMID: 38769169. doi:10.1007/s11060-024-04702-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。