不同呼气末正压水平对伴或不伴中线移位的幕上开颅手术患者视神经鞘直径的影响
这项前瞻性观察研究纳入80例18-70岁ASA I-III级幕上开颅手术患者,全麻诱导后分别在呼气末正压(PEEP)0、5、10 cmH2O下测量视神经鞘直径(ONSD)。结果显示ONSD随PEEP升高而增加(p<0.001),伴与不伴中线移位患者间ONSD无差异;但中线移位患者应用10 cmH2O PEEP时平均ONSD达5.73 mm,略高于颅内压升高 cutoff 下限。
要点
- ONSD随PEEP水平升高而增加(p<0.001)。
- 伴与不伴中线移位患者各PEEP水平下ONSD无差异。
- 中线移位患者10 cmH2O PEEP时平均ONSD 5.73 mm,略高于cutoff下限。
核心结论
- 成人幕上肿瘤开颅手术中,PEEP至5 cmH2O似乎与颅内压升高无关;但中线移位患者应用10 cmH2O PEEP时ONSD超过颅内压升高的cutoff值。
研究设计与样本
- 前瞻性观察研究,纳入80例18-70岁ASA I-III级择期幕上开颅手术患者,全麻诱导后于PEEP 0、5、10 cmH2O下用线阵探头在眼球下3 mm处测量ONSD,比较伴中线移位(n=7)与不伴中线移位(n=73)患者不同PEEP值下的ONSD。
主要发现
- ONSD随PEEP水平升高而增加(p<0.001)。
- 伴与不伴中线移位患者在不同PEEP值下ONSD比较无差异(p分别为0.329、0.535、0.410)。
- 中线移位患者应用10 cmH2O PEEP时平均ONSD为5.73 mm,比ONSD cutoff值下限约高0.1 mm。
关键数值与推荐
- ONSD评估颅内压升高的cutoff值为5.6至6.3 mm。
- PEEP 0、5、10 cmH2O下测量ONSD,测量位置为眼球下3 mm处。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: In general, high levels of PEEP application is avoided in patients undergoing craniotomy to prevent a rise in ICP. But that approach would increase the risk of secondary brain injury especially in hypoxemic patients. Because the optic nerve sheath is distensible, a rise in ICP is associated with an increase in the optic nerve sheath diameter (ONSD). The cutoff value for elevated ICP assessed by ONSD is between 5.6 and 6.3 mm. We aimed to evaluate the effect of different PEEP levels on ONSD and compare the effect of different PEEP levels in patients with and without intracranial midline shift. METHODS: This prospective observational study was performed in aged 18-70 years, ASA I-III, 80 patients who were undergoing supratentorial craniotomy. After the induction of general anesthesia, the ONSD's were measured by the linear transducer from 3 mm below the globe at PEEP values of 0-5-10 cmH2O. The ONSD were compered between patients with (n = 7) and without midline shift (n = 73) at different PEEP values. RESULTS: The increases in ONSD due to increase in PEEP level were determined (p < 0.001). No difference was found in the comparison of ONSD between patients with and without midline shift in different PEEP values (p = 0.329, 0.535, 0.410 respectively). But application of 10 cmH2O PEEP in patients with a midline shift increased the mean ONSD value to 5.73 mm. This value is roughly 0.1 mm higher than the lower limit of the ONSD cutoff value. CONCLUSIONS: The ONSD in adults undergoing supratentorial tumor craniotomy, PEEP values up to 5 cmH2O, appears not to be associated with an ICP increase; however, the ONSD exceeded the cutoff for increased ICP when a PEEP of 10 cmH2O was applied in patients with midline shift.
引用
- Fenerci A, Akcil EF, Tunali Y, et al. Effect of different positive end expiratory pressure levels on optic nerve sheath diameter in patients with or without midline shift who are undergoing supratentorial craniotomy. Acta Neurochir (Wien). 2024. PMID: 38622368. doi:10.1007/s00701-024-06067-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。