文献速递小儿神经外科与脑积水功能神经外科

无狭窄或梗阻的窄室间孔患者神经内镜下进入第三脑室:室间孔成形术的作用

Neuroendoscopic access to the third ventricle in patients with narrow foramen of monro without stenosis/obstruction: role of foraminoplasty.
PubMed 文献 · Acta Neurochir (Wien) · 2024-04-29

本文回顾本中心2018年以来神经内镜手术中术前影像示室间孔直径<6 mm且无梗阻或狭窄并接受室间孔成形术的病例,共6例,技术成功率为全部完成手术且无宏观结构损伤,术后3个月随访无认知或记忆异常,作者认为室间孔成形术可降低内镜通过室间孔时的并发症风险。

要点

  • 术前影像示室间孔直径<6 mm且无梗阻或狭窄者,可考虑行室间孔成形术以辅助内镜通过。
  • 本组6例均技术成功,无室间孔结构宏观损伤,术后3个月认知测试无异常。
  • 作者认为室间孔成形术可降低窄室间孔患者内镜手术并发症风险。

核心结论

  • 对于无狭窄或梗阻征象的窄室间孔患者,室间孔成形术是降低内镜系统通过该结构时并发症风险的有用技术,使神经内镜手术得以安全实施。

研究设计与样本

  • 回顾本中心2018年以来开展的神经内镜手术,纳入术前影像示室间孔直径<6 mm且无梗阻或狭窄并应用室间孔成形术的病例,评估技术成功与功能成功,并复习文献中描述的各种室间孔成形术式。

主要发现

  • 共识别6例术前室间孔直径<6 mm且无梗阻或狭窄的患者,均计划行室间孔成形术以辅助各种脑室内神经内镜手术。
  • 全部病例均成功完成技术操作,未对构成室间孔的各个结构造成宏观损伤。
  • 随访认知测试评估穹窿微损伤相关后遗症,无患者出现异常。

关键数值与推荐

  • 技术成功定义为完成神经内镜手术且构成室间孔的各结构无宏观损伤、随访影像无并发症。
  • 功能成功定义为术后3个月随访期间无认知或记忆改变。

临床怎么用

  • 作者认为,对无狭窄或梗阻征象的窄室间孔患者,室间孔成形术是降低内镜通过时并发症风险的有用技术。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECT: One of the critical steps for the success of intraventricular neuroendoscopic procedures is the entry into the third ventricle and passage of the endoscopy system through the foramen of Monro (FM). A diameter larger than that of the instrument used is considered a prerequisite for safely performing the technique, as damage to this structure can lead to alterations in the fornix and vascular structures. When the foramen diameter is narrow and there is no obstruction/stenosis, the role of foraminoplasty in reducing the risk of complications has not been adequately assessed in the literature. METHODS: A review of endoscopic procedures conducted at our center since 2018 was undertaken. Cases in which preoperative imaging indicated a FM diameter < 6 mm and foraminoplasty technique was applied were examined to determine the technical and functional success of the procedure. The technical success was determined by completing the neuroendoscopic procedure with the absence of macroscopic lesions in the various structures comprising the foramen and without complications in the follow-up imaging tests. Functional success was defined as the absence of cognitive/memory alterations during the 3-month postoperative follow-up. Additionally, a review of the various forms of foraminoplasty described in the literature is conducted. RESULTS: In our cohort, six patients were identified with a preoperative FM diameter < 6 mm without obstruction or stenosis. Foraminoplasty was planned for these cases to facilitate various intraventricular neuroendoscopic procedures. In all instances, the technique was successfully performed without causing macroscopic damage to the structures comprising the foramen. Follow-up visits included various cognitive tests to assess potential sequelae related to microscopic damage to the fornix. None of the patients exhibited anomalies. CONCLUSION: Foraminoplasty in patients with a narrow FM without signs of stenosis/obstruction is a useful technique to reduce the risk of complications during the passage of the endoscopy system through this structure, enabling the safe performance of neuroendoscopic procedures.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Guil-Ibáñez JJ, Gomar-Alba M, García-Pérez F, et al. Neuroendoscopic access to the third ventricle in patients with narrow foramen of monro without stenosis/obstruction: role of foraminoplasty. Acta Neurochir (Wien). 2024. PMID: 38683412. doi:10.1007/s00701-024-06077-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。