文献速递功能神经外科

术中加速度测量与实时分析工具用于磁共振引导聚焦超声丘脑毁损术

An intraoperative accelerometry and real-time analysis tool for magnetic resonance-guided focused ultrasound thalamotomy.
PubMed 文献 · J Neurosurg · 2024-04-19

该研究展示了一种与磁共振兼容的加速度计及配套MATLAB分析代码和图形界面,可在磁共振引导聚焦超声丘脑毁损术术中近实时记录、可视化和量化特发性震颤。该方法用于20例手术,患者治疗侧肢体按临床震颤评定量表改善50.7%(95%CI -64.1%至-37.3%),且不中断手术。

要点

  • 该加速度计与磁共振兼容,配合MATLAB分析代码和图形界面,可近实时记录、可视化和量化震颤。
  • 该方法在20例手术中使用,患者治疗侧肢体按临床震颤评定量表改善50.7%(95%CI -64.1%至-37.3%)。
  • 该方法不中断手术,且为定量评估,结果可导出保存供后续回顾。

核心结论

  • 该加速度测量与实时分析工具可在磁共振引导聚焦超声丘脑毁损术中不中断手术地定量记录和量化震颤变化,为优化治疗提供快速客观反馈。

研究设计与样本

  • 研究展示了一种与磁共振兼容的加速度计及配套MATLAB分析代码和图形用户界面,用于在磁共振引导聚焦超声丘脑毁损术中近实时记录、可视化和量化震颤,结果可导出保存。

主要发现

  • 该方法用于20例手术,患者治疗侧肢体按临床震颤评定量表改善50.7%(95%CI -64.1%至-37.3%)。
  • 该方法不中断手术,且为定量评估,结果可导出保存供后续回顾。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Magnetic resonance-guided focused ultrasound (MRgFUS) is one of the newest surgical treatments for essential tremor (ET). During this procedure, a lesion is created within the thalamus to mitigate tremor. Targeting is done using a combination of stereotaxy, MR tractography, and sublesional heating, with tremor assessed during the procedure to gauge therapeutic effectiveness. Currently, tremor assessments are done qualitatively, but this approach requires the tremor change to be above a subjective threshold and provides no objective record of surgical tremor progression. Here, the authors present and demonstrate an MR-compatible accelerometer with custom MATLAB analysis code and graphical user interface to record, visualize, and quantify tremor in near real-time. Results can be exported and saved for future review. This method was used in 20 surgeries, with patients experiencing a 50.7% (95% CI -64.1% to -37.3%) improvement in the treated limb per the Clinical Rating Scale for Tremor. This method does not interrupt the surgery and is quantitative. As research on optimizing MRgFUS treatment for ET continues-for example, the refinement of targeting during sublesional sonications-such quantifying and recording of tremor changes will provide rapid and objective feedback.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Swytink-Binnema CA, Coreas A, Pichardo S, et al. An intraoperative accelerometry and real-time analysis tool for magnetic resonance-guided focused ultrasound thalamotomy. J Neurosurg. 2024. PMID: 38626471. doi:10.3171/2024.1.JNS231830

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。