低剖面可视化腔内支撑装置用于宽颈颅内动脉瘤Y型支架辅助栓塞:单中心经验
该单中心回顾性研究纳入40例40个宽颈颅内动脉瘤,评估LVIS装置Y型支架辅助栓塞的长期造影与临床结局;术后即刻完全/近完全闭塞(RROC 1和2)31个(77.5%),长期随访32例中RROC 1和2占93.8%,围手术期并发症5例(12.5%),最终随访36例(90.0%)临床结局良好。
要点
- 40个动脉瘤中术后即刻RROC 1和2为31个(77.5%),长期随访32例中RROC 1和2占93.8%。
- Y型支架辅助栓塞后分叉分支间夹角从171.90°±48.0°降至130.21°±46.3°(P<0.0001)。
- 围手术期并发症5例(12.5%),其中支架内血栓4例(10.5%);最终随访36例(90.0%)临床结局良好。
核心结论
- 使用LVIS装置的Y型支架辅助栓塞治疗颅内分叉部动脉瘤是可行且相对安全的手术,具有较好的长期造影和临床结局。
研究设计与样本
- 单中心回顾性研究,回顾性分析接受LVIS支架Y型支架辅助栓塞患者的临床表现和造影数据,共纳入40例患者40个动脉瘤。
主要发现
- 术后即刻造影显示31个动脉瘤(77.5%)达到完全/近完全闭塞(RROC 1和2)。
- 长期随访造影在32例患者中进行,93.8%的患者为RROC 1和2。
- Y型支架辅助栓塞使用LVIS装置使分叉分支间夹角从171.90°±48.0°显著降至130.21°±46.3°(P<0.0001)。
- 围手术期并发症发生在5例患者(12.5%),包括4例支架内血栓(10.5%)。
- 最终随访时36例患者(90.0%)临床结局良好;单因素分析显示世界神经外科医师联盟分级3-5级、头颅CT上蛛网膜下腔出血厚度、术中并发症和支架内血栓是不良结局的预测因素。
临床怎么用
- 作者认为,使用LVIS装置的Y型支架辅助栓塞治疗颅内分叉部动脉瘤是可行且相对安全的手术,具有较好的长期造影和临床结局。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The Low-Profile Visualized Intraluminal Support (LVIS) device has been frequently used as an intracranial stent for treating intracranial aneurysms. However, the feasibility and efficacy of LVIS devices in Y-stent-assisted coiling (Y-SAC) have remained contentious. This study aimed to evaluate long-term angiographic and clinical outcomes of Y-SAC using LVIS devices. METHODS: We retrospectively reviewed the clinical presentation and angiography data of patients treated with Y-SAC using LVIS stents. The vascular angle geometry between the parent and the 2 branch vessels, before and after stent deployment and after coiling, were analyzed. Based on the Raymond-Roy Occlusion Classification (RROC), aneurysm occlusion status was classified. Clinical outcomes were assessed using the modified Rankin Scale. RESULTS: Forty patients with 40 aneurysms were included in this study. Immediate postprocedural angiograms showed complete/near-complete occlusion (RROC 1 and 2) in 31 aneurysms (77.5%). The long-term follow-up angiographic studies were available in 32 patients and showed RROC class 1 and 2 in 93.8% of patients. Y-SAC with LVIS devices significantly decreased the angle between the bifurcation branches from 171.90° ± 48.0° (standard deviation) to 130.21° ± 46.3° (standard deviation) (P < 0.0001). Periprocedural complications occurred in 5 patients (12.5%) including 4 in-stent thromboses (10.5%). Thirty-six patients (90.0%) had favorable clinical outcomes at the final follow-up. Univariate analysis showed that World Federation of Neurological Societies grade 3-5, thickness of subarachnoid hemorrhage on head computed tomography, intraprocedural complications, and in-stent thrombosis were predictors of poor outcome. CONCLUSIONS: Y-SAC using the LVIS device for intracranial bifurcation aneurysms is a feasible and relatively safe procedure with favorable long-term angiographic and clinical outcomes.
引用
- Saghebdoust S, Qoorchi Moheb Seraj F, Najafi S, et al. Low-Profile Visualized Intraluminal Support Device for Y-Stent-Assisted Coiling of Wide-Neck Intracranial Aneurysms: A Single-Center Experience. World Neurosurg. 2024. PMID: 38677648. doi:10.1016/j.wneu.2024.04.122
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。