乙状窦后开颅夹闭血流导向术后未闭塞的小脑后下动脉动脉瘤
本文报告一例小脑后下动脉动脉瘤患者,既往使用单枚Pipeline栓塞装置行血流导向治疗,随访超过1年动脉瘤未闭塞,随后采用乙状窦后开颅行动脉瘤夹闭术,并讨论了入路选择、夹闭技巧及支架保留等要点。
要点
- 血流导向装置置入后动脉瘤未闭塞时,瘤囊被装置阻挡,弹簧圈等瘤内装置难以使用。
- 该例小脑后下动脉动脉瘤经单枚Pipeline装置治疗随访超过1年未闭塞,改行乙状窦后开颅夹闭。
- 文中讨论了入路选择、动脉瘤夹闭及支架保留的技术细节。
核心结论
- 血流导向装置使用不当可因瘤囊被阻挡而给后续治疗造成困难,血流导向治疗失败的动脉瘤仍可继续增大和破裂。
- 在条件允许时,手术夹闭可成为最简单、最持久的解决方案。
研究设计与样本
- 本文为病例报告,报告一例既往以单枚Pipeline栓塞装置行血流导向治疗、随访超过1年动脉瘤未闭塞的小脑后下动脉动脉瘤患者,随后行乙状窦后开颅动脉瘤夹闭术。
主要发现
- 该患者的小脑后下动脉动脉瘤经单枚Pipeline栓塞装置血流导向治疗,随访超过1年未闭塞。
- 随后采用乙状窦后开颅行动脉瘤夹闭术,文中讨论了入路选择、动脉瘤夹闭及支架保留的细节。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Flow diversion (FD) has revolutionized the treatment of cerebral aneurysms. Since the introduction of the Pipeline Embolization Device, there has been a significant shift in the management of cerebral aneurysms, with increasing emphasis being placed on use of endoluminal reconstruction as a means of long-term, durable treatment of aneurysms. Increasingly, FD stents are being used as primary treatment for aneurysms, including those that present with subarachnoid hemorrhage.1 Improper use of FD stents, however, may create havoc, as access to the aneurysm sac is blocked with the placement of these devices. Aneurysms that are incompletely treated with FD may continue to grow and rupture. The inability to use coils or endosaccular devices for treatment of these aneurysms means the only options for treatment are placement of additional FD devices, deconstructive strategies with or without bypass, or microsurgical clipping,2 thereby making an aneurysm that may have been straightforward to treat with another strategy a complex lesion to treat with the presence of the FD stent. Although deconstructive techniques can be used for treatment of failed aneurysm occlusion with flow diversion, where possible, surgical clipping can result in the simplest, most durable solution. Herein we present (Video 1) a case of a patient with a posterior inferior cerebellar artery aneurysm treated previously with FD using a single pipeline embolization device without aneurysm occlusion over 1 year of follow-up who was treated with retrosigmoid craniotomy and clipping of aneurysm. Nuances of the approach selection, clipping of the aneurysm, and preservation of the stent are discussed.
引用
- Kalani MYS. Retrosigmoid Craniectomy for Clip Ligation of Flow-Diverted Posterior Inferior Cerebellar Artery Aneurysm. World Neurosurg. 2024. PMID: 38608814. doi:10.1016/j.wneu.2024.04.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。