文献速递脑血管病外科神经重症

基底动脉穿支动脉瘤:与非穿支囊状动脉瘤的比较

Basilar artery perforator aneurysms: a comparison with non-perforator saccular aneurysms.
PubMed 文献 · Acta Neurochir (Wien) · 2024-03-19

本研究基于前瞻性神经血管数据库,回顾性比较了9例基底动脉穿支动脉瘤(BAPA)与103例后循环非穿支动脉瘤所致动脉瘤性蛛网膜下腔出血(aSAH)患者。BAPA在CT上血容量与对照组相似,CT血管成像(CTA)易漏诊,血管壁成像(VWI)上强化明显;多数自发血栓形成,初始保守治疗、仅在增大时干预,与无再出血或并发症相关。

要点

  • BAPA占aSAH患者9/739例,男性比例高于后循环非穿支动脉瘤对照组(6/9,p=0.008)。
  • 6/9例BAPA在CTA上最初被漏诊,VWI上呈明显强化, stalk ratio 1.05±0.12,高于未破裂动脉瘤(0.43±0.11,p<0.001)。
  • 所有BAPA初始保守治疗,6例自发血栓形成,3例增大后经颞下开颅手术治疗无并发症,无再出血。

核心结论

  • 尽管BAPA体积小,但其所致SAH的血容量、WFNS分级和脑积水与其他动脉瘤相似;CTA难以识别,但VWI上强化显著。
  • 多数BAPA自发血栓形成;初始保守治疗、仅在增大时干预,与无再出血或并发症相关。

研究设计与样本

  • 病例来自前瞻性神经血管数据库,回顾性查阅病历和影像,并与连续的非穿支动脉瘤患者系列进行比较。
  • 比较CT上的血容量和血管壁成像(VWI),并与对照组比较。

主要发现

  • 739例aSAH患者中9例(9/739)患有BAPA。
  • 与103例后循环动脉瘤所致aSAH患者相比,BAPA患者更可能为男性(6/9,p=0.008),但严重程度相当(4/9为差分级,p=0.736),需要脑脊液引流的比例相当(5/9,p=0.154)。
  • 血容量与对照组相似(30.2 ml vs 26.7 ml,p=0.716)。
  • 6/9例BAPA最初在CTA上被漏诊;VWI显示厚(2.9 mm ± 2.7)亮强化(stalk ratio 1.05 ± 0.12),与破裂动脉瘤对照组相似(0.95 ± 0.23,p=0.551),但高于未破裂动脉瘤(0.43 ± 0.11,p<0.001)。
  • 所有BAPA初始均保守治疗;6例自发血栓形成;3例增大,因入路困难且血管内治疗选择少,经颞下开颅手术治疗无并发症;无再出血。

临床怎么用

  • 作者指出,初始保守治疗、仅在增大时干预,与无再出血或并发症相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Basilar artery perforator aneurysms (BAPAs) are rare. There is no systematic description of their presentation, imaging, natural history and outcomes and how these compare to conventional non-perforator aneurysms. Thus, the authors in this study aimed to compare BAPAs to non-perforator aneurysms. METHODS: Cases were identified from a prospective neurovascular database, notes and imaging retrospectively reviewed and compared to a consecutive series of patients with non-perforator aneurysms. Blood volume on CT and vessel wall imaging (VWI) were compared to controls. RESULTS: 9/739 patients with aneurysmal subarachnoid haemorrhage (aSAH) harboured BAPAs. Compared to 103 with aSAH from posterior circulation aneurysms, they were more likely to be male (6/9, p = 0.008), but of equal severity (4/9 poor grade, p = 0.736) and need of CSF drainage (5/9, p = 0.154). Blood volume was similar to controls (30.2 ml vs 26.7 ml, p = 0.716). 6/9 BAPAs were initially missed on CTA. VWI showed thick (2.9 mm ± 2.7) bright enhancement (stalk ratio 1.05 ± 0.12), similar to controls with ruptured aneurysms (0.95 ± 0.23, p = 0.551), and greater than unruptured aneurysms (0.43 ± 0.11, p < 0.001). All were initially managed conservatively. Six thrombosed spontaneously. Three grew and had difficult access with few good endovascular options and were treated through a subtemporal craniotomy without complication. None rebled. At 3 months, all presenting in poor grade were mRS 3-4 and those in good grade mRS 1-2. CONCLUSIONS: Despite their small size, BAPAs present with similar volume SAH, WFNS grade and hydrocephalus to other aneurysms. They are difficult to identify on CTA but enhance strikingly on VWI. The majority thrombosed. Initial conservative management reserving treatment for growth was associated with no rebleeds or complications.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Kaldas A, Zolnourian A, Ewbank F, et al. Basilar artery perforator aneurysms: a comparison with non-perforator saccular aneurysms. Acta Neurochir (Wien). 2024. PMID: 38499881. doi:10.1007/s00701-024-06026-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。