文献速递神经肿瘤功能神经外科

应用3-T术中磁共振成像最大程度切除毗邻皮质脊髓束的胶质瘤

Maximal Resection of Gliomas Adjacent to the Corticospinal Tract Using 3-T Intraoperative Magnetic Resonance Imaging.
PubMed 文献 · World Neurosurg · 2024-03-20

前瞻性评估3-T术中磁共振联合运动诱发电位在毗邻皮质脊髓束胶质瘤手术中的切除程度及切除腔与皮质脊髓束距离,27例中26例实现全切除,切除程度98.6%,运动功能稳定或改善组术中最小距离显著长于恶化组。

要点

  • 3-T术中磁共振联合导航和运动诱发电位可辅助毗邻皮质脊髓束胶质瘤的最大程度切除。
  • 27例中26例实现全切除,体积分析切除程度达98.6%。
  • 运动功能稳定或改善组术中最小距离7.3 mm显著长于恶化组1.1 mm(P < 0.05)。

核心结论

  • 使用3-T术中磁共振导航系统切除毗邻皮质脊髓束的胶质瘤可实现最终切除程度超过98%。
  • 术中纤维束成像联合运动诱发电位有助于最大程度切除运动区胶质瘤。

研究设计与样本

  • 前瞻性研究,纳入63例接受手术患者中的27例幕上单发胶质瘤且位于皮质脊髓束10 mm以内者。
  • 所有病例在运动诱发电位监测下使用叠加皮质脊髓束的神经导航手术。
  • 采用Spearman秩相关计算皮质脊髓束距离与经皮层运动诱发电位波幅的相关性。

主要发现

  • 27例中26例实现全切除,体积分析显示切除程度为98.6%。
  • 运动功能稳定或改善24例(稳定/改善组),恶化3例(恶化组)。
  • 恶化组所有患者术前均有运动功能障碍。
  • 稳定/改善组术中最小距离均值7.3 mm显著长于恶化组1.1 mm(P < 0.05)。
  • 运动诱发电位波幅与切除腔至皮质脊髓束最小距离相关(R = 0.64)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Gliomas adjacent to the corticospinal tract (CST) should be carefully resected to preserve motor function while achieving maximal surgical resection. Modern high-field intraoperative magnetic resonance imaging (iMRI) enables precise visualization of the residual tumor and intraoperative tractography. We prospectively evaluated the extent of resection and distance between the tumor resection cavity and CST using 3-T iMRI combined with motor evoked potentials (MEP) in glioma surgery. METHODS: Participants comprised patients who underwent surgery for solitary supratentorial glioma located within 10 mm of the CST. All cases underwent surgery using neuronavigation with overlaid CST under MEP monitoring. The correlation between distance from CST and transcortical MEP amplitude was calculated using Spearman rank correlation. RESULTS: Among the 63 patients who underwent surgery, 27 patients were enrolled in the study. Gross total resections were achieved in 26 of the 27 cases. Volumetric analysis showed the extent of resection was 98.6%. Motor function was stable or improved in 24 patients (Stable/Improved group) and deteriorated in 3 patients (Deteriorated group). All patients in the Deteriorated group showed motor deficit before surgery. Mean intraoperative minimal distance was significantly longer in the Stable/Improved group (7.3 mm) than in the Deteriorated group (1.1 mm; P < 0.05). MEP amplitude correlated with minimal distance between the resection cavity and CST (R = 0.64). CONCLUSIONS: Resection of gliomas adjacent to CST with a navigation system using 3-T iMRI could result in an ultimate EOR >98%. The combination of intraoperative tractography and MEP contributes to maximal removal of motor-eloquent gliomas.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Hanihara M, Kawataki T, Kazama H, et al. Maximal Resection of Gliomas Adjacent to the Corticospinal Tract Using 3-T Intraoperative Magnetic Resonance Imaging. World Neurosurg. 2024. PMID: 38519017. doi:10.1016/j.wneu.2024.03.058

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。