MRI三维SPACE T2WI序列用于诊断垂体腺瘤海绵窦侵袭
本研究评估MRI三维SPACE T2WI序列在垂体腺瘤海绵窦侵袭诊断中的价值,纳入2019年10月至2021年2月本院连续垂体MRI检查患者。结果显示该序列海绵窦成像质量优于增强T1WI和平扫T2WI(P<0.05),基于海绵窦内侧壁完整性的诊断灵敏度100%、特异度90.0%、阳性预测值55.60%、阴性预测值100.0%,准确率94.40%。
要点
- 3D SPACE T2WI海绵窦成像质量优于增强T1WI和平扫T2WI(P<0.05)
- 基于海绵窦内侧壁完整性的诊断灵敏度100%、特异度90.0%
- 阳性预测值55.60%、阴性预测值100.0%、准确率94.40%
核心结论
- 3D SPACE T2WI平扫序列上海绵窦内侧壁成像质量优于增强T1WI TSE增强扫描和平扫T2WI TSE序列
- 连续观察海绵窦内侧壁对该序列评估垂体腺瘤海绵窦侵袭具有较大诊断价值,较传统MRI观察指标更可靠
研究设计与样本
- 收集2019年10月至2021年2月本院医学影像中心连续垂体MRI检查患者数据
- 对符合条件病例在INFINITT PACS工作站上评估矢状位和轴位T1WI序列、冠状位3D SPACE T2WI序列及矢状位和冠状位增强T1WI序列
- 采用配对样本Wilcoxon符号秩检验和两独立样本Mann-Whitney U检验分析各组图像质量评分差异
- 将各观察指标的灵敏度、特异度、阳性预测值和阴性预测值与术中结果进行比较
主要发现
- 3D SPACE T2WI海绵窦成像质量优于增强T1WI和平扫T2WI(P<0.05)
- 基于海绵窦内侧壁完整性的诊断灵敏度100%、特异度90.0%、阳性预测值55.60%、阴性预测值100.0%
- 基于海绵窦内侧壁完整性的垂体腺瘤侵袭性诊断准确率94.40%
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This study aims to assess the utility of magnetic resonance imaging (MRI) 3D SPACE T2-weighted imaging (T2WI) sequences in evaluating cavernous sinus invasion by pituitary adenomas. METHODS: Data were collected from patients who underwent continuous pituitary MRIexaminations at the Medical Imaging Center of our hospital from October 2019 to February 2021. Eligible cases were evaluated for sagittal and axial T1WI sequences, coronal 3D SPACE T2WI sequences, and sagittal and coronal enhanced T1-weighted imaging (T1WI) sequences using the INFINITT PACS workstation. The Wilcoxon signed-rank test for paired samples and the Mann-Whitney U test for 2 independent samples were used to statistically analyze differences in image quality scores among various groups. In addition, the sensitivity, specificity, positive predictive value, and negative predictive value of each observation index were compared with intraoperative results. RESULTS: 3D SPACE T2WI showed superior cavernous sinus imaging quality compared with contrast enhanced T1WI and T2WI plain scans (P < 0.05). The sensitivity, specificity, positive predictive value, and negative predictive value were 100%, 90.0%, 55.60%, and 100.0%, respectively. The accuracy for pituitary adenoma invasiveness diagnosis based on cavernous sinus medial wall integrity was 94.40%. CONCLUSIONS: The imaging quality of the medial wall of the cavernous sinus on the 3D SPACE T2WI plain scan sequence surpassed that of contrast enhanced T1WI TSE-enhanced scans and T2WI TSE plain scans. The continuous observation of the medial wall of the cavernous sinus using this sequence holds great diagnostic value for assessing cavernous sinus invasion by pituitary adenomas. This strategy is more reliable than traditional MRI observation indicators.
引用
- Chen Y, Cai S, Li X, et al. MRI 3D SPACE T2WI for Pituitary Adenoma Cavernous Sinus Invasion Diagnosis. World Neurosurg. 2024. PMID: 38514027. doi:10.1016/j.wneu.2024.03.066
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。