文献速递神经肿瘤

内镜下5-氨基乙酰丙酸诱导荧光引导的脑实质内肿瘤切除——内镜能否比显微镜检测到更多荧光?

Endoscopic 5-Aminolevulinic Acid-Induced Fluorescence-Guided Intraparenchymal Brain Tumor Resection-Can the Endoscope Detect More Fluorescence Than the Microscope?
PubMed 文献 · World Neurosurg · 2024-03-19

该研究通过实验室光学装置比较内镜与显微镜对5-氨基乙酰丙酸(5ALA)荧光的检测能力,并前瞻性收集2012至2023年间45例患者共49次完全内镜下5ALA引导脑实质内肿瘤切除术的临床资料。结果显示内镜在短工作距离下蓝光强度更高、荧光检测阈值更低,临床切除安全可行,80%病例切除程度大于95%,42%达到全切除。

要点

  • 内镜在小于20 mm工作距离下蓝光强度高于显微镜。
  • 内镜定量荧光检测阈值在30 mm和10 mm距离下均低于显微镜。
  • 45例患者共49次内镜5ALA引导切除术,80%切除大于95%,42%全切除,1例新发神经功能缺损。

核心结论

  • 与显微镜相比,内镜对5ALA诱导荧光提供增强的可视化和检测,完全内镜下5ALA引导的脑实质内肿瘤切除安全可行。

研究设计与样本

  • 实验室光学装置比较蔡司Pentero显微镜与Karl Storz Hopkins内镜,并前瞻性收集2012至2023年间所有连续完全内镜下5ALA引导脑实质内肿瘤切除术的临床资料,共45例患者49次手术(平均年龄41岁,男性28例)。

主要发现

  • 在工作距离小于20 mm时,内镜照射样本的蓝光强度大于显微镜。
  • 在30 mm和10 mm工作距离下,内镜的定量荧光检测阈值均低于显微镜。
  • 显微镜的荧光检测阈值为相对浓度0.65%-0.80%(3.20×10-7至3.94×10-7 mol/dm-3);内镜在30 mm处为相对浓度0.40%-0.55%(1.97×10-7至2.71×10-7 mol/dm-3);内镜在10 mm处为相对浓度0.15%-0.30%(7.40×10-8至1.48×10-7 mol/dm-3)。
  • 80%病例实现大于95%的切除,42%实现全切除。
  • 非功能区肿瘤的全切除率为100%。

临床怎么用

  • 作者认为内镜较显微镜能增强5ALA诱导荧光的可视化与检测,完全内镜下5ALA引导的脑实质内肿瘤切除安全可行。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Using a laboratory-based optical setup, we show that 5-aminolevulinic acid (5ALA) fluorescence is better detected using the endoscope than the microscope. Furthermore, we present our case series of fully endoscopic 5ALA-guided resection of intraparenchymal tumors. METHODS: A Zeiss Pentero microscope was compared with the Karl Storz Hopkins endoscope. The spectra and intensity of each blue light source were measured. Quantitative fluorescence detection thresholds were measured using a spectrometer. Subjective fluorescence detection thresholds were measured by 6 blinded neuro-oncology surgeons. Clinical data were prospectively collected for all consecutive cases of fully endoscopic 5ALA-guided resection of intraparenchymal tumors between 2012 and 2023. RESULTS: The intensity of blue light on the sample was greater for the endoscope than the microscope at working distances less than 20 mm. The quantitative fluorescence detection thresholds were lower for the endoscope than the microscope at both 30-/10-mm working distances. Fluorescence detection threshold was 0.65%-0.80% relative 4-dicyanomethylene-2-methyl-6-p-dimethylaminostyryl-4H-pyranthe concentration (3.20 × 10-7 to 3.94 × 10-7mol/dm-3) for the microscope, 0.40%-0.55% relative concentrations (1.97 × 10-7 to 2.71 × 10-7mol/dm-3) for the endoscope at 30 mm, and 0.15%-0.30% relative concentrations (7.40 × 10-8 to 1.48 × 10-7mol/dm-3) for the endoscope at 10 mm. In total, 49 5ALA endoscope-assisted brain tumor resections were carried out on 45 patients (mean age = 41 years, male = 28). Greater than 95% resection was achieved in 80% of cases and gross total resection in 42%. Gross total resection was achieved in 100% of tumors in noneloquent locations. There was 1 new neurologic deficit. CONCLUSIONS: The endoscope provides enhanced visualization/detection of 5ALA-induced fluorescence compared with the microscope. 5ALA endoscopic-assisted resection of intraparenchymal tumors is safe and feasible.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Ma R, Livermore LJ, Taylor L, et al. Endoscopic 5-Aminolevulinic Acid-Induced Fluorescence-Guided Intraparenchymal Brain Tumor Resection-Can the Endoscope Detect More Fluorescence Than the Microscope? World Neurosurg. 2024. PMID: 38514030. doi:10.1016/j.wneu.2024.03.067

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。