框架式与机器人辅助立体定向脑电图在药物难治性癫痫中的比较

Frame-based versus robot-assisted stereo-electro-encephalography for drug-resistant epilepsy.
PubMed 文献 · Acta Neurochir (Wien) · 2024-02-16

本研究回顾性纳入2014至2022年接受立体定向脑电图(SEEG)电极植入的药物难治性局灶性癫痫患者,比较传统Leksell框架式与机器人辅助SEEG的精度、效率与安全性。机器人辅助组目标点定位误差中位数更低(1.8 mm vs 2.8 mm,P<0.001),手术时间更短(77.5 min vs 90 min,P<0.01),总并发症率与主要并发症率两组无显著差异。

要点

  • 机器人辅助SEEG目标点定位误差中位数1.8 mm,低于框架式的2.8 mm(P<0.001)。
  • 机器人辅助SEEG手术时间中位数77.5 min,短于框架式的90 min(P<0.01)。
  • 总并发症率框架式17.7% vs 机器人辅助11.5%,主要并发症率3.5% vs 7.7%,均无显著差异。

核心结论

  • SEEG是安全且高度准确的方法,为癫痫手术提供重要指导;联合多模态规划系统与机器人设备可进一步提高安全边际、手术效率与精度。

研究设计与样本

  • 回顾性纳入2014至2022年接受SEEG深部电极植入的药物难治性局灶性癫痫患者,共166例患者、167次SEEG手术;前141次采用Leksell立体定向系统的传统方法,后26次为机器人辅助。

主要发现

  • 共植入1726根深部电极,入口点定位误差中位数框架式1.0 mm(范围0.1-33.5 mm)vs 机器人辅助1.1 mm(范围0-4.8 mm),P=0.17。
  • 目标点定位误差中位数框架式2.8 mm(范围0.1-49 mm)vs 机器人辅助1.8 mm(范围0-30.3 mm),P<0.001。
  • 手术时间中位数机器人辅助77.5 min vs 框架式90 min,P<0.01。
  • 总并发症率框架式17.7% vs 机器人辅助11.5%,P=0.57;主要并发症率框架式3.5% vs 机器人辅助7.7%,P=0.77。

临床怎么用

  • 原文结论认为SEEG是安全且高度准确的方法,联合多模态规划系统与机器人设备可进一步提高安全边际、手术效率与精度;原文未据此给出具体推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Stereoelectroencephalography (SEEG) is an effective presurgical invasive evaluation for drug-resistant epilepsies. The introduction of robotic devices provides a simplified, accurate, and safe alternative to the conventional SEEG technique. We report our institutional experience with robot-assisted SEEG and compare its in vivo accuracy, operation efficiency, and safety with the more traditional SEEG workflow. METHODS: All patients with medically refractory focal epilepsy who underwent SEEG depth electrode implantation between 2014 and 2022 were included in this study. Technical advancements of the robot-assisted technique are described. Analyses of patient demographics, electrode implantation accuracy, operation time, and procedure-related complications were performed. RESULTS: One hundred and sixty-six patients underwent 167 SEEG procedures. The first 141 procedures were performed using a conventional approach involving a Leksell stereotactic system, and the last 26 procedures were robot-assisted. Among the 1726 depth electrodes that were inserted, the median entry point localization error was as follows: conventional (1.0 mm; range, 0.1-33.5 mm) and robot-assisted (1.1 mm; range, 0-4.8 mm) (P = 0.17). The median target point localization error was as follows: conventional (2.8 mm; range, 0.1-49 mm) and robot-assisted (1.8 mm; range, 0-30.3 mm) (P < 0.001). The median operation time was significantly reduced with the robot-assisted workflow (90 min vs. 77.5 min; P < 0.01). Total complication rates were as follows: conventional (17.7%) and robot-assisted (11.5%) (P = 0.57). Major complication rates were 3.5% and 7.7% (P = 0.77), respectively. CONCLUSIONS: SEEG is a safe and highly accurate method that provides essential guidance for epilepsy surgery. Implementing SEEG in conjunction with multimodal planning systems and robotic devices can further increase safety margin, surgical efficiency, and accuracy.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Han CL, Chou CC, Chen HH, et al. Frame-based versus robot-assisted stereo-electro-encephalography for drug-resistant epilepsy. Acta Neurochir (Wien). 2024. PMID: 38361129. doi:10.1007/s00701-024-05983-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。