利用脑光电容积描记图估算创伤性脑损伤患者颅内压的初步临床研究
本研究开发了一种基于红外光的光学非侵入性颅内压(nICP)传感器,在40例接受有创ICP监测的患者中同步评估,采用Bland-Altman分析和ROC曲线计算nICP准确性。nICP估计与有创ICP的95%一致性界限为3.8 mmHg,相关性为0.8254,ROC曲线分析显示灵敏度80%、特异度89%。
要点
- 光学nICP传感器在创伤性脑损伤患者中可无创估算颅内压。
- nICP与有创ICP的95%一致性界限为3.8 mmHg,相关性0.8254。
- ROC分析示灵敏度80%、特异度89%,作者认为准确性临床可用。
核心结论
- 该光学nICP传感器的临床评估显示其能以可接受且临床有用的准确性无创估算ICP,为后续技术优化和更大规模临床研究打开大门。
研究设计与样本
- 初步临床研究,首次将有创ICP监测作为金标准同步评估nICP探头,对40例接受有创ICP监测的患者进行nICP监测,数据随机拆分用于机器学习。
主要发现
- 成功采集创伤性脑损伤患者的脑光电容积描记图(PPG)信号,并开发了bagging tree模型以无创估算nICP。
- nICP估计与有创ICP监测的95%一致性界限为3.8 mmHg,偏倚极小,相关性为0.8254。
- ROC曲线分析显示灵敏度80%、特异度89%。
关键数值与推荐
- 提取高质量PPG信号并分析基于时间的特征。
- 采用Bland-Altman分析和ROC曲线计算评估nICP与有创ICP数据相比的准确性。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: In this research, a non-invasive intracranial pressure (nICP) optical sensor was developed and evaluated in a clinical pilot study. The technology relied on infrared light to probe brain tissue, using photodetectors to capture backscattered light modulated by vascular pulsations within the brain's vascular tissue. The underlying hypothesis was that changes in extramural arterial pressure could affect the morphology of recorded optical signals (photoplethysmograms, or PPGs), and analysing these signals with a custom algorithm could enable the non-invasive calculation of intracranial pressure (nICP). METHODS: This pilot study was the first to evaluate the nICP probe alongside invasive ICP monitoring as a gold standard. nICP monitoring occurred in 40 patients undergoing invasive ICP monitoring, with data randomly split for machine learning. Quality PPG signals were extracted and analysed for time-based features. The study employed Bland-Altman analysis and ROC curve calculations to assess nICP accuracy compared to invasive ICP data. RESULTS: Successful acquisition of cerebral PPG signals from traumatic brain injury (TBI) patients allowed for the development of a bagging tree model to estimate nICP non-invasively. The nICP estimation exhibited 95% limits of agreement of 3.8 mmHg with minimal bias and a correlation of 0.8254 with invasive ICP monitoring. ROC curve analysis showed strong diagnostic capability with 80% sensitivity and 89% specificity. CONCLUSION: The clinical evaluation of this innovative optical nICP sensor revealed its ability to estimate ICP non-invasively with acceptable and clinically useful accuracy. This breakthrough opens the door to further technological refinement and larger-scale clinical studies in the future. TRIAL REGISTRATION: NCT05632302, 11th November 2022, retrospectively registered.
引用
- Roldan M, Abay TY, Uff C, et al. A pilot clinical study to estimate intracranial pressure utilising cerebral photoplethysmograms in traumatic brain injury patients. Acta Neurochir (Wien). 2024. PMID: 38409283. doi:10.1007/s00701-024-06002-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。