文献速递神经肿瘤

术中脑涂片诊断准确性的Meta分析:来自资源有限地区的研究

Diagnostic Accuracy of Intraoperative Brain Smear: A Meta-Analysis of Studies from Resource-Limited Settings.
PubMed 文献 · World Neurosurg · 2024-01-10

结论认为术中脑涂片在资源有限地区同样是有用且准确的快速诊断方法。

要点

  • 纳入12项研究共1124例患者,均来自低中收入国家。
  • 作者认为术中脑涂片在资源有限地区同样是准确的快速诊断方法。

核心结论

  • 术中脑涂片在资源丰富地区是准确、敏感的诊断方法,在资源有限地区同样有用,是理想的快速诊断方法。

研究设计与样本

  • 系统检索PubMed、Google Scholar、Scopus、CINAHL和Embase,纳入低中收入国家中具有检验性能特征的术中脑涂片研究。
  • 共纳入12项研究、1124例患者;6项同时包含成人与儿童,4项仅成人,2项仅儿童。
  • 采用分层总结受试者工作特征曲线(ROC)及随机效应模型汇总数据。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Intraoperative brain smear is an easy, rapid, and cost-effective technique for immediate diagnosis of brain tumors. Earlier studies have gauged its application on limited number of samples, but its diagnostic accuracy especially in low-resource settings, where its practice would be extremely helpful, is still undetermined. To investigate the diagnostic accuracy of intraoperative brain smear in resource-limited settings for diagnosis of brain tumors. METHODS: A systematic search was conducted on PubMed, Google Scholar, Scopus, Cumulative Index to Nursing and Allied Health Literature (CINAHL), and Embase for all articles utilizing intraoperative brain smears that were extracted. Studies from low- and middle-income countries (LMICs) with test performance characteristics were selected and subsequent values were summarized using a hierarchical summary receiver operating characteristic (ROC) curve via STATA and pooled using a random-effects model on MetaDiSc 2.0. RESULTS: Twelve studies consisting of 1124 patients were identified. Six studies included both adult and pediatric population groups, while 4 investigated adults and 2 included pediatric patients. The pooled diagnostic odds ratio (OR) was calculated to be 212.52 (CI: [104.27-433.13]) of Bivariable pooled specificity and sensitivity were 92% (CI: [86%-96%]) and 96% (CI: [93%-98%]), respectively. CONCLUSIONS: Our study shows that intraoperative brain smear is not only an accurate and sensitive diagnostic modality in resource-rich settings, but it is also equally useful in resource-limited settings, making it an ideal method for rapid diagnosis.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Shakir M, Irshad HA, Lodhi BA, et al. Diagnostic Accuracy of Intraoperative Brain Smear: A Meta-Analysis of Studies from Resource-Limited Settings. World Neurosurg. 2024. PMID: 38211813. doi:10.1016/j.wneu.2024.01.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。