神经肿瘤术中导航超声:体积准确性及与高场强MRI的相关性
一项前瞻性研究纳入80例成人脑内轴内肿瘤患者(88个病灶),评估导航术中超声(nioUS)测量肿瘤体积和检测残留病灶的能力。术前nioUS与MRI体积高度相关(R²=0.97,p<0.001),术后残留病灶相关性较弱但仍显著(R²=0.78,p<0.001)。作者认为nioUS是可靠的术中技术,可用于实时监测肿瘤切除和残留病灶体积分析。
要点
- 术前nioUS与MRI肿瘤体积几乎完全相关(R²=0.97,p<0.001)。
- 术后残留病灶nioUS与MRI相关性较弱但仍显著(R²=0.78,p<0.001)。
- 超声可见度显著影响相关性,高度可见(3级)肿瘤相关性更强(p=0.01)。
核心结论
- 大多数脑肿瘤在nioUS下边界清晰,术前和术后与MRI测量几乎完全相关,nioUS是可靠的术中技术,可用于实时监测肿瘤切除和残留病灶体积分析。
研究设计与样本
- 前瞻性研究,纳入2017年11月至2020年10月接受轴内脑肿瘤手术的成人患者80例(女35例,男45例,平均年龄58岁,范围25-80岁),评估88个病灶。
- 使用凸阵(5-8 MHz)和线阵(6-13 MHz)探头行导航术中超声,测量肿瘤体积和残留病灶,与MRI比较。
- 采用基于机器学习流程的线性回归模型和Bland-Altman分析评估nioUS与MRI的准确性。
主要发现
- 88个病灶中胶质瘤64个(73%)、转移瘤19个(21.6%)、其他肿瘤5个(5.7%),多位于额叶(41%)和颞叶(27%)。
- 75%的肿瘤在ioUS上完美可见(Mair分级3级),岛叶肿瘤为2级。
- 术前MRI与nioUS肿瘤体积几乎完全相关(R²=0.97,p<0.001),超声可见度显著影响该相关性,高度可见(3级)肿瘤相关性更强(p=0.01)。
- 术后MRI与nioUS残留肿瘤相关性较弱(R²=0.78,p<0.001)但具统计学显著性。
- Bland-Altman分析显示两种技术在术前和术后场景偏倚极小,术前一致性具统计学显著性。
临床怎么用
- 作者认为nioUS是可靠的术中技术,可用于实时监测脑肿瘤切除和残留病灶体积分析。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The use of intraoperative techniques to detect residual tumors has recently become increasingly important. Intraoperative MRI has long been considered the gold standard; however, it is not widely used because of high equipment costs and long acquisition times. Consequently, real-time intraoperative ultrasound (ioUS), which is much less expensive than MRI, has gained popularity. The aim of the present study was to evaluate the capacity of ioUS to accurately determine the primary tumor volume and detect residual tumors. METHODS: A prospective study of adult patients who underwent surgery for intra-axial brain tumors between November 2017 and October 2020 was performed. Navigated intraoperative ultrasound (nioUS) of the brain was used to guide tumor resection and to detect the presence of residual disease. Both convex (5-8 MHz) and linear array (6-13 MHz) probes were used. Tumor volume and residual disease were measured with nioUS and compared with MR images. A linear regression model based on a machine learning pipeline and a Bland-Altman analysis were used to assess the accuracy of nioUS versus MRI. RESULTS: Eighty patients (35 females and 45 males) were included. The mean age was 58 years (range 25-80 years). A total of 88 lesions were evaluated; there were 64 (73%) gliomas, 19 (21.6%) metastases, and 5 (5.7%) other tumors, mostly located in the frontal (41%) and temporal (27%) lobes. Most of the tumors (75%) were perfectly visible on ioUS (grade 3, Mair grading system), except for those located in the insular lobe (grade 2). The regression model showed a nearly perfect correlation (R2 = 0.97, p < 0.001) between preoperative tumor volumes from both MRI and nioUS. Ultrasonographic visibility significantly influenced this correlation, which was stronger for highly visible (grade 3) tumors (p = 0.01). For residual tumors, the correlation between postoperative MRI and nioUS was weaker (R2 = 0.78, p < 0.001) but statistically significant. The Bland-Altman analysis showed minimal bias between the two techniques for pre- and postoperative scenarios, with statistically significant results for the preoperative concordance. CONCLUSIONS: The authors' findings show that most brain tumors are well delineated by nioUS and almost perfectly correlated with MRI-based measurements both pre- and postoperatively. These data support the hypothesis that nioUS is a reliable intraoperative technique that can be used for real-time monitoring of brain tumor resections and to perform volumetric analysis of residual disease.
引用
- Aibar-Duran JA, Salgado-López L, Anka-Tugbiyele MO, et al. Navigated intraoperative ultrasound in neuro-oncology: volumetric accuracy and correlation with high-field MRI. J Neurosurg. 2024. PMID: 38181499. doi:10.3171/2023.10.JNS231244
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。