通过可解释人工智能确定脑动脉瘤栓塞后再通的重要三维血流动力学特征

Determination of Significant Three-Dimensional Hemodynamic Features for Postembolization Recanalization in Cerebral Aneurysms Through Explainable Artificial Intelligence.
PubMed 文献 · World Neurosurg · 2024-01-20

本研究基于58个动脉瘤的计算机流体动力学模拟,使用PointNet深度神经网络自动识别栓塞前/后模型的速度、压力和壁面剪切应力等参数,并用显著性映射进行可解释分析。速度被确定为最关键的参数,其统计P值最低且DNN模型的ROC/PR曲线下面积最高。可解释分析显示,栓塞前模型中的强注入流区及撞击点、血流动力学与弹簧圈平面的相互作用是识别再通动脉瘤的重要三维特征。

要点

  • 速度是预测栓塞后再通的最关键血流动力学参数。
  • 深度神经网络结合可解释人工智能可准确预测再通。
  • 强注入流区及血流与弹簧圈平面相互作用是重要三维特征。

核心结论

  • 深度神经网络与可解释人工智能的结合是一种准确且可解释的方法,不仅能预测栓塞后再通,还能在未来发现未知特征。

研究设计与样本

  • 本研究分析了58个动脉瘤的计算机流体动力学模拟,涵盖栓塞前和栓塞后模型。
  • 采用基于PointNet的深度神经网络自动识别重要血流动力学参数,并利用显著性映射进行可解释人工智能分析。

主要发现

  • 速度被确定为最关键的参数,其统计分析P值最低,且深度神经网络模型的ROC曲线和PR曲线下面积最高。
  • 视觉可解释分析显示,栓塞前模型中具有显著撞击点的强注入流区,以及血流动力学与弹簧圈平面之间明显的相互作用,是识别再通动脉瘤的重要三维特征。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Recanalization poses challenges after coil embolization in cerebral aneurysms. Establishing predictive models for postembolization recanalization is important for clinical decision making. However, conventional statistical and machine learning (ML) models may overlook critical parameters during the initial selection process. METHODS: In this study, we automated the identification of significant hemodynamic parameters using a PointNet-based deep neural network (DNN), leveraging their three-dimensional spatial features. Further feature analysis was conducted using saliency mapping, an explainable artificial intelligence (XAI) technique. The study encompassed the analysis of velocity, pressure, and wall shear stress in both precoiling and postcoiling models derived from computational fluid dynamics simulations for 58 aneurysms. RESULTS: Velocity was identified as the most pivotal parameter, supported by the lowest P value from statistical analysis and the highest area under the receiver operating characteristic curves/precision-recall curves values from the DNN model. Moreover, visual XAI analysis showed that robust injection flow zones, with notable impingement points in precoiling models, as well as pronounced interplay between flow dynamics and the coiling plane, were important three-dimensional features in identifying the recanalized aneurysms. CONCLUSIONS: The combination of DNN and XAI was found to be an accurate and explainable approach not only at predicting postembolization recanalization but also at discovering unknown features in the future.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Liao J, Misaki K, Uno T, et al. Determination of Significant Three-Dimensional Hemodynamic Features for Postembolization Recanalization in Cerebral Aneurysms Through Explainable Artificial Intelligence. World Neurosurg. 2024. PMID: 38246531. doi:10.1016/j.wneu.2024.01.076

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。