文献速递脑血管病外科

颅内动脉瘤三维形态学参数的系统综述与Meta分析

A Systematic Review and Meta-Analysis of 3-Dimensional Morphometric Parameters for Cerebral Aneurysms.
PubMed 文献 · World Neurosurg · 2023-12-30

该系统综述与Meta分析通过PRISMA指南检索15,122篇文章,最终纳入39项研究,识别17项三维形态学参数,其中11项纳入Meta分析。Meta分析显示非球形指数、波动指数、伸长率、平坦度和球形度与破裂状态相关性最一致。

要点

  • 非球形指数、波动指数、伸长率、平坦度和球形度与动脉瘤破裂状态相关性最一致。
  • 椭圆指数和体积的发表偏倚风险显著(P=0.0360和P=0.0030)。
  • 共识别17项三维形态学参数,其中11项符合Meta分析条件。

核心结论

  • 基于包含39项研究的Meta分析,非球形指数、波动指数、伸长率、平坦度和球形度与破裂状态的相关性最一致。

研究设计与样本

  • 两位独立评价者按照PRISMA指南进行文献检索,以识别报告颅内动脉瘤三维形态学参数与破裂状态关联的文章。
  • 共识别15,122篇文章,筛选后纳入39项研究。

主要发现

  • 非球形指数与破裂状态显著相关(SMD 0.66,95%CI 0.53-0.79,P<0.0001,I²=55.2%)。
  • 波动指数与破裂状态显著相关(SMD 0.55,95%CI 0.26-0.85,P=0.0017,I²=68.1%)。
  • 椭圆指数与破裂状态显著相关(SMD 0.53,95%CI 0.29-0.77,P=0.0005,I²=70.8%)。
  • 体积与破裂状态显著相关(SMD 0.18,95%CI 0.02-0.35,P=0.0320,I²=82.3%)。
  • 体积/开口比与破裂状态显著相关(SMD 0.43,95%CI 0.16-0.71,P=0.0075,I²=90.4%)。

关键数值与推荐

  • 伸长率与破裂状态显著相关(SMD -0.94,95%CI -1.12至-0.76,P=0.0005,I²=0%)。
  • 平坦度与破裂状态显著相关(SMD -0.87,95%CI -1.04至-0.71,P=0.0005,I²=0%)。
  • 球形度与破裂状态显著相关(SMD -0.62,95%CI -1.06至-0.17,P=0.0215,I²=67.9%)。
  • 椭圆指数(P=0.0360)和体积(P=0.0030)估计存在显著发表偏倚风险。

局限性

  • 椭圆指数(P=0.0360)和体积(P=0.0030)估计存在显著发表偏倚风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Imaging modalities with increased spatial resolution have allowed for more precise quantification of cerebral aneurysm shape in 3-dimensional (3D) space. We conducted a systematic review and meta-analysis to assess the correlation of individual 3D morphometric measures with cerebral aneurysm rupture status. METHODS: Two independent reviewers performed a PRISMA (preferred reporting items of systematic reviews and meta-analysis)-guided literature search to identify articles reporting the association between 3D morphometric measures of intracranial aneurysms and rupture status. RESULTS: A total of 15,122 articles were identified. After screening, 39 studies were included. We identified 17 3D morphometric measures, with 11 eligible for the meta-analysis. The meta-analysis showed a significant association with rupture status for the following measures: nonsphericity index (standardized mean difference [SMD], 0.66; 95% confidence interval [CI], 0.53-0.79; P < 0.0001; I2 = 55.2%), undulation index (SMD, 0.55; 95% CI, 0.26-0.85; P = 0.0017; I2 = 68.1%), ellipticity index (SMD, 0.53; 95% CI, 0.29-0.77; P = 0.0005; I2 = 70.8%), volume (SMD, 0.18; 95% CI, 0.02-0.35; P = 0.0320; I2 = 82.3%), volume/ostium ratio (SMD, 0.43; 95% CI, 0.16-0.71; P = 0.0075; I2 = 90.4%), elongation (SMD, -0.94; 95% CI, -1.12 to -0.76; P = 0.0005; I2 = 0%), flatness (SMD, -0.87; 95% CI, -1.04 to -0.71; P = 0.0005; I2 = 0%), and sphericity (SMD, -0.62; 95% CI, -1.06 to -0.17; P = 0.0215; I2 = 67.9%). A significant risk of publication bias was estimated for the ellipticity index (P = 0.0360) and volume (P = 0.0030). CONCLUSIONS: Based on the results of a meta-analysis containing 39 studies, the nonsphericity index, undulation index, elongation, flatness, and sphericity demonstrated the most consistent correlation with rupture status.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Johnson MD, Palmisciano P, Yamani AS, et al. A Systematic Review and Meta-Analysis of 3-Dimensional Morphometric Parameters for Cerebral Aneurysms. World Neurosurg. 2023. PMID: 38160907. doi:10.1016/j.wneu.2023.12.131

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。