文献速递脑血管病外科

评估Contour囊内装置治疗脑动脉瘤的疗效与并发症:多中心分析

Evaluating Efficacy and Complications of Contour Intrasaccular Device in Cerebral Aneurysm Management: A Multicenter Analysis.
PubMed 文献 · World Neurosurg · 2024-01-07

该多中心回顾性分析纳入3家医院25例接受Contour囊内装置治疗的脑动脉瘤患者,评估其疗效与并发症;15例(65.5%)在栓塞后1年获得满意血管造影结果(0-0'级),但存在装置移位等并发症及再治疗需求,作者认为该装置可行但需注意学习曲线。

要点

  • 25例患者中15例(65.5%)栓塞后1年达满意血管造影结果(0-0'级)。
  • 术中并发症如装置移位见于3例(12%),装置附着聚集2例(8%)。
  • 晚期并发症包括装置移位5例(20%)和轻微卒中1例(4%)。

核心结论

  • Contour装置为复杂动脉瘤的治疗提供了可行选择,早期结果有前景,但需注意学习曲线以减少并发症并获得满意血管造影结果而无需额外治疗。

研究设计与样本

  • 对3家医院中心25例接受Contour装置治疗的患者进行回顾性分析,收集年龄、性别、基线改良Rankin量表、个人习惯、病史、手术细节及按Woven endobridge闭塞量表评估的血管造影结果。

主要发现

  • 15例患者(65.5%)在栓塞后1年获得满意血管造影结果(0-0'级)。
  • 14例患者(58.3%)观察到对比剂滞留。
  • 术中并发症如装置移位记录于3例患者(12%),2例患者(8%)有聚集体附着于装置。
  • 晚期并发症方面,5例患者(20%)发生装置移位,1例患者发生轻微卒中(4%)。
  • 3例患者(12%)需要再治疗,涉及血流导向装置、支架和弹簧圈。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Intrasaccular devices provide a method for treating complex aneurysms without leaving metallic materials in the parent artery. Compared to other well-studied devices in neurointervention, the Contour device is relatively new as an intrasaccular flow diverter. This study examines its use in cases of incidental aneurysms and its application in the acute treatment of ruptured aneurysms. Additionally, it covers potential complications that may arise and methods for prevention. METHODS: We conducted a retrospective analysis of 25 patients who underwent treatment with the Contour device at 3 hospital centers. We collected data related to age, gender, baseline modified Rankin Scale, personal habits, medical history, procedure details, and angiographic results according to the Woven endobridge occlusion scale. RESULTS: A total of 15 patients (65.5%) achieved a satisfactory angiographic result (grade 0-0') 1 year after embolization. Contrast stagnation was observed in 14 patients (58.3%). Intraprocedural complications, such as device displacement, were documented in 3 patients (12%), while 2 patients (8%) had aggregates attached to the device. Regarding late complications, 5 patients (20%) experienced device displacement and 1 patient had a minor stroke (4%). Retreatment was necessary for 3 patients (12%), involving a flow diverter, stenting, and coiling. CONCLUSIONS: In summary, the Contour device offers a viable option for treating complex aneurysms. While initial results are promising, it is crucial to acknowledge a learning curve to minimize complications and achieve satisfactory angiographic results without the need for additional treatments.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Gallo-Pineda F, Fernández-Gómez M, Domínguez-Rodríguez C, et al. Evaluating Efficacy and Complications of Contour Intrasaccular Device in Cerebral Aneurysm Management: A Multicenter Analysis. World Neurosurg. 2024. PMID: 38195027. doi:10.1016/j.wneu.2024.01.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。