文献速递功能神经外科

用于经颅磁共振引导聚焦超声手术核团定位的新型高精度纤维束成像:一项先导研究

A novel high-precision fiber tractography for nuclear localization in transcranial magnetic resonance-guided focused ultrasound surgery: a pilot study.
PubMed 文献 · J Neurosurg · 2023-11-10

这项回顾性先导研究纳入20例接受经颅磁共振引导聚焦超声手术的患者,比较广义q采样成像(GQI)与弥散张量成像(DTI)算法可视化纤维束的效果,并分析纤维束与病灶重叠体积和震颤改善及不良事件的关系,认为GQI作为计划影像有潜力提高靶点精度并获得良好临床结局。

要点

  • GQI算法较DTI算法可显示更高质量的纤维束,DTI对运动皮层纤维可视化不充分。
  • 病灶与Vim纤维重叠体积和震颤改善程度呈强相关(r=0.72)。
  • 病灶内Vim纤维重叠体积达401 mm3与良好临床结局相关,Vc和PT重叠体积99 mm3与避免不良事件相关。

核心结论

  • 这项先导研究提示,将高精度GQI算法纤维束成像作为经颅磁共振引导聚焦超声手术的计划影像技术,有潜力提高靶点定位精度并获得良好临床结局。

研究设计与样本

  • 回顾性研究,纳入20例接受经颅磁共振引导聚焦超声手术的患者。
  • 于治疗前、治疗后24小时及3-6个月评估震颤临床评定量表(CRST)评分和MR图像。
  • 按不良事件有无及严重程度分为无不良事件、无需额外治疗的轻度不良事件和需延长住院的严重不良事件。
  • 用DTI和GQI算法可视化Vim、Vc和PT纤维束,测量Vim纤维与病灶重叠体积并行相关分析。
  • 分析病灶内Vc和PT纤维重叠体积与不良事件的关系,并用受试者工作特征曲线确定界值。

主要发现

  • 所有患者治疗后24小时震颤均改善,3例发生轻度不良事件,1例发生严重不良事件。
  • 3-6个月随访时5例复发,2例持续存在轻度不良事件。
  • DTI算法对运动皮层纤维可视化不充分,GQI算法可显示显著更高质量的纤维。
  • 病灶与Vim纤维重叠体积和震颤改善程度呈强相关(r=0.72)。
  • 病灶内Vc和PT重叠体积越高与不良事件可能性增加相关(p < 0.05);良好临床结局的病灶内Vim纤维界值为401 mm3,避免不良事件的病灶内Vc和PT体积界值为99 mm3。

关键数值与推荐

  • 良好临床结局的病灶内Vim纤维重叠体积界值为401 mm3。
  • 避免不良事件的病灶内Vc和PT重叠体积界值为99 mm3。
  • 病灶与Vim纤维重叠体积和震颤改善程度相关系数r=0.72。
  • 病灶内Vc和PT重叠体积与不良事件关联的p < 0.05。

临床怎么用

  • 作者认为,将高精度GQI算法纤维束成像作为经颅磁共振引导聚焦超声手术的计划影像技术,有潜力提高靶点定位精度并获得良好临床结局。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: In transcranial MR-guided focused ultrasound (TcMRgFUS), fiber tractography using diffusion tensor imaging (DTI) has been proposed as a direct method to identify the ventral intermediate nucleus (Vim), the ventral caudal nucleus (Vc), and the pyramidal tract (PT). However, the limitations of the DTI algorithm affect the accuracy of visualizing anatomical structures due to its low-quality fiber tractography, whereas the application of the generalized q-sampling imaging (GQI) algorithm enables the visualization of high-quality fiber tracts, offering detailed insights into the spatial distribution of motor cortex fibers. This retrospective study aimed to investigate the usefulness of high-precision fiber tractography using the GQI algorithm as a planning image in TcMRgFUS to achieve favorable clinical outcomes. METHODS: This study included 20 patients who underwent TcMRgFUS. The Clinical Rating Scale for Tremor (CRST) scores and MR images were evaluated pretreatment and at 24 hours and 3-6 months after treatment. Cases were classified based on the presence and adversity of adverse events (AEs): no AEs, mild AEs without additional treatment, and severe AEs requiring prolonged hospitalization. Fiber tractography of the Vim, Vc, and PT was visualized using the DTI and GQI algorithm. The overlapping volume between Vim fibers and the lesion was measured, and correlation analysis was performed. The relationship between AEs and the overlapping volume of the Vc and PT fibers within the lesions was examined. The cutoff value to achieve a favorable clinical outcome and avoid AEs was determined using receiver operating characteristic curve analysis. RESULTS: All patients showed improvement in tremors 24 hours after treatment, with 3 patients experiencing mild AEs and 1 patient experiencing severe AEs. At the 3- to 6-month follow-up, 5 patients experienced recurrence, and 2 patients had persistent mild AEs. Although fiber visualization in the motor cortex using the DTI algorithm was insufficient, the GQI algorithm enabled the visualization of significantly higher-quality fibers. A strong correlation was observed between the overlapping volume that intersects the lesion and Vim fibers and the degree of tremor improvement (r = 0.72). Higher overlapping volumes of Vc and PT within the lesion were associated with an increased likelihood of AEs (p < 0.05); the cutoff volume of Vim fibers within the lesion for a favorable clinical outcome was 401 mm3, while the volume of Vc and PT within the lesion to avoid AEs was 99 mm3. CONCLUSIONS: This pilot study suggests that incorporating the high-precision GQI algorithm for fiber tractography as a planning imaging technique for TcMRgFUS has the potential to enhance targeting precision and achieve favorable clinical outcomes.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Hori H, Taira T, Abe K, et al. A novel high-precision fiber tractography for nuclear localization in transcranial magnetic resonance-guided focused ultrasound surgery: a pilot study. J Neurosurg. 2023. PMID: 37948701. doi:10.3171/2023.8.JNS231459

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。