一致性是关键:颅骨密度比分布对MR引导聚焦超声治疗后临床有效病灶形成及长期震颤抑制的影响
本研究回顾性分析61例接受MR引导聚焦超声靶向Vim治疗的特发性或肌张力障碍性震颤患者,采用线性混合效应模型分析颅骨密度比(SDR)直方图指标对震颤抑制的影响。结果显示SDR峰度与CRST和HTS改善显著正相关,且与12个月时病灶体积更大、体积缩小更少相关。结论认为SDR峰度可能比平均SDR更具预后价值。
要点
- SDR峰度与CRST改善(β=0.33,p=0.004)及HTS改善(β=0.38,p<0.001)显著正相关。
- SDR峰度越高,12个月时病灶体积越大且相对第1天体积缩小越少(p=0.040和p=0.007)。
- SDR峰度可能比平均SDR提供更有意义的预后信息。
核心结论
- 较高的SDR峰度与治疗后12个月更大、更稳定的病灶以及长期随访中更强的震颤抑制相关。
- SDR峰度可能提供比平均SDR更有意义的预后因素。
研究设计与样本
- 回顾性分析61例接受MR引导聚焦超声靶向Vim治疗的特发性或肌张力障碍性震颤患者的数据。
主要发现
- SDR峰度与CRST改善显著正相关(β=0.33,p=0.004),与HTS改善显著正相关(β=0.38,p<0.001)。
- 治疗后1个月时效应显著:CRST(β=0.415,p=0.008),HTS(β=0.369,p=0.016)。
- 最近一次临床随访时效应显著:CRST(β=0.395,p<0.001),HTS(β=0.386,p<0.001)。
- 逐元件分析识别出171个显著元件,这些元件与平均SDR的平均百分比差异与CRST改善(β=0.27,p<0.008)和HTS改善(β=0.27,p<0.015)相关。
- 较高的SDR峰度与12个月时病灶体积增大(p=0.040)及相对第1天病灶体积缩小更少(p=0.007)相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Skull density ratio (SDR) influences the permeability of the skull to the ultrasound waves used in magnetic resonance-guided focused ultrasound (MRgFUS) for the treatment of tremor. SDR values vary across the skull and the mean value is known to be predictive of sonication thermal increase. The aim of this investigation was to explore the effects of the SDR distribution on clinical outcomes following treatment with MRgFUS. METHODS: Data from 61 patients with essential or dystonic tremor treated with MRgFUS targeting the ventral intermediate nucleus (Vim) were retrospectively analyzed. Tremor suppression was assessed using the Clinical Rating Scale for Tremor (CRST) and hand tremor score (HTS). Vim ablation volume was measured on the T1-weighted MR image acquired both at 1 day and 12 months after treatment. The numerical distribution of SDR values measured for each element in the ultrasound transducer was quantified by calculating the mean, standard deviation, skewness, entropy, and kurtosis of the SDR histogram. The effect of the SDR metrics on change in CRST and HTS was examined using a linear mixed-effects model. Additionally, the effect of the regional distribution of SDR values was explored in an element-wise analysis between patients with above- and below-average tremor suppression. RESULTS: A significant positive effect was found between SDR kurtosis and improvement in CRST (β = 0.33, p = 0.004) and HTS (β = 0.38, p < 0.001). The effect was found to be significant at 1 month posttreatment (CRST: β = 0.415, p = 0.008; HTS: β = 0.369, p = 0.016), and at the most recent clinical follow-up (CRST: β = 0.395, p < 0.001; HTS: β = 0.386, p < 0.001). One hundred seventy-one significant elements were identified in the element-wise analysis. The mean percentage difference from the mean SDR in these elements was associated with improvement in CRST (β = 0.27, p < 0.008) and HTS (β = 0.27, p < 0.015). Higher SDR kurtosis was associated with increased lesion volume at 12 months (p = 0.040) and less reduction in volume relative to the day-1 lesion volume (p = 0.007). CONCLUSIONS: Greater SDR kurtosis was associated with larger, more stable lesions at 12 months posttreatment and increased tremor suppression at long-term follow-up. SDR kurtosis may provide a more meaningful prognostic factor than the mean SDR.
引用
- Kyle K, Maamary J, Jonker B, et al. Consistency is key: influence of skull density ratio distribution on the formation of clinically effective lesions and long-term tremor suppression following treatment with MR-guided focused ultrasound. J Neurosurg. 2023. PMID: 37657096. doi:10.3171/2023.6.JNS231153
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。