外视镜在面肌痉挛和三叉神经痛微血管减压术中的功能性与可用性
七名神经外科医生用视觉模拟量表(VAS,1-10,5分等同手术显微镜质量)评估4K三维数字外视镜在微血管减压术中的功能性与可用性。外视镜功能性优于手术显微镜(P<0.001),术中视疲劳评分显著更高(P<0.001),而手术时间、出院结局和术后1年结局在两者间无统计学差异。
要点
- 外视镜在微血管减压术中的功能性优于手术显微镜(P<0.001)。
- 外视镜术中视疲劳VAS评分显著高于手术显微镜(P<0.001)。
- 外视镜与手术显微镜在手术时间、出院结局和术后1年结局上无统计学差异。
核心结论
- 神经外科医生在使用外视镜行微血管减压术时可能经历更低的压力水平。
- 由于外视镜微血管减压术的结局与手术显微镜相比未显示统计学差异,外视镜可能被证明是实施微血管减压术的有用工具。
研究设计与样本
- 七名神经外科医生通过回答问卷评估4K三维数字外视镜在微血管减压术中的有用性。
- 问卷利用视觉模拟量表(VAS;1-10)询问外视镜的功能性与可用性,VAS评分5分等同于手术显微镜的相应质量。
- 通过每位神经外科医生前3例和后3例手术的平均VAS评分评估外视镜的学习效应。
主要发现
- 外视镜在微血管减压术中的功能性优于手术显微镜(P<0.001)。
- 在最后3例手术中,外视镜在手臂操作便利性、手术器械交换、手术操作便利性和术中体力压力方面的平均VAS评分优异。
- 外视镜在术中视疲劳方面的平均VAS评分显著高于手术显微镜(P<0.001)。
- 使用外视镜与手术显微镜行微血管减压术在手术时间、出院结局和术后1年结局方面未发现统计学显著性。
关键数值与推荐
- VAS评分5分等同于手术显微镜的相应质量。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Studies on the functionality and usability of the exoscope in neurosurgical procedures against surgical microscopes (SMs) are limited. This study aimed to examine the functionality and usability of the exoscope during microvascular decompression (MVD) surgery. METHODS: Seven neurosurgeons evaluated the usefulness of a 4 K, 3-dimension digital exoscope in MVD by answering a questionnaire. The questionnaire inquired about the functionality and usability of the exoscope by utilizing a visual analog scale (VAS; 1-10). A score of 5 on VAS was equivalent to the corresponding quality of the SM. The learning effect of the exoscope was evaluated using mean VAS scores in the first and last 3 cases for each neurosurgeon. RESULTS: The functionality of the exoscope in MVD was superior to that in SM (P < 0.001). In the last 3 surgeries, the mean VAS scores of the exoscope were excellent in terms of ease of arm handling, exchange of surgical instruments, ease of surgical procedure, and intraoperative physical stress. The mean VAS scores of the exoscope in intraoperative asthenopia were significantly higher than those of the SM (P < 0.001). No statistical significance was found in operation time, discharge outcome, and 1-year post-surgery outcome between MVD performed using the exoscope and SM. CONCLUSIONS: Neurosurgeons may experience reduced stress levels during MVD when using the exoscope. As the outcome of MVD using the exoscope did not demonstrate a statistical difference compared with MVD using the SM, the exoscope may prove to be a useful tool for performing MVD.
引用
- Hashikata H, Maki Y, Futamura G, et al. Functionality and Usability of the Exoscope in Microvascular Decompression for Hemifacial Spasm and Trigeminal Neuralgia. World Neurosurg. 2023. PMID: 37683924. doi:10.1016/j.wneu.2023.08.138
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。