非可调压分流阀治疗交通性脑积水与三维容积测量:一项回顾性分析
该回顾性分析评估了2014至2020年间首次置入非可调压阀治疗交通性脑积水的41例患者,分析分流翻修率、改良Rankin量表临床结局及基于Evans指数和三维半自动分割脑室容积的影像学演变。结果显示分流相关翻修率为17.1%,68.3%患者mRS改善≥1分,脑室容积显著缩小但与mRS改善无相关性,作者认为三维半自动分割脑室容积可用于检测交通性脑积水患者脑室容积的微小变化。
要点
- 41例交通性脑积水患者首次置入非可调压阀,分流相关翻修率为17.1%。
- 68.3%患者改良Rankin量表评分改善1分或以上。
- Evans指数与三维半自动分割脑室容积相关性良好,脑室容积显著缩小,但与mRS改善无相关性。
核心结论
- 作者认为非可调压阀在分流翻修率及临床和影像学演变方面的结果与文献相当。
- 三维半自动分割脑室容积可用于检测交通性脑积水患者脑室容积的微小变化。
研究设计与样本
- 回顾性分析2014至2020年间所有因交通性脑积水首次置入非可调压阀的病例。
- 共41例患者,平均年龄65岁(范围25-89岁),共实施59次手术,包括12例患者中的18次翻修手术(29.3%)。
主要发现
- 交通性脑积水病因包括出血后(61%)、创伤后(24.4%)和肿瘤性(14.6%)。
- 首次分流翻修的原因为阀门类型相关(阀门功能障碍、过度引流和引流不足)和非阀门类型相关(位置不当、感染和分流管移位)。
- 分流相关翻修率为17.1%。
- 28例患者(68.3%)改良Rankin量表评分改善1分或以上。
- Evans指数与三维半自动分割脑室容积相关性良好,Evans指数和三维半自动分割脑室容积测得的脑室容积均显著缩小,但mRS改善与脑室容积缩小无相关性。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Although the use of different types of valves has been extensively studied in shunt surgery for communicating hydrocephalus (cHC), a consensus about the valve type remains absent. The objective of this study is to evaluate our results with the primary placement of nonprogrammable valves (NPVs) for this indication. METHODS: We retrospectively analyzed all first NPVs implanted between 2014 and 2020 for cHC. We studied the revision rate, clinical outcome described by modified Rankin Scale (mRS), and radiologic evolution using Evans Index (EI) and ventricular volumes three-dimensional semi-automatic segmentation (vv-3DSAS). RESULTS: Forty-one patients were shunted for posthemorrhagic (61%), posttraumatic (24.4%), and tumoral (14.6%) hydrocephalus. Mean age was 65 years (range, 25-89 years). Overall, 59 procedures were performed including 18 revision surgeries in 12 patients (29.3%). The underlying reasons for first shunt revision were valve type related (valve dysfunction, overdrainage, and underdrainage) and nonvalve type related (malpositioning, infection, and shunt migration). The shunt-related revision rate was 17.1%. Twenty-eight patients (68.3%) had an mRS score improvement of 1 or more points. We found a good correlation between ventricle volumes (VV) and EI and a significant reduction in VV measured by EI and vv-3DSAS was observed. However, the mRS improvement was not correlated with a reduction in ventricle volumes. CONCLUSIONS: Overall, our results in terms of shunt revisions as well as clinical and radiologic evolution are comparable to the literature for NPV. vv-3DSAS can be used and could be useful to detect small changes in VV in patients with cHC.
引用
- Cortier J, Van Der Straeten R, Van Gestel F, et al. Nonprogrammable Shunts for Communicating Hydrocephalus and Three-Dimensional Volumetry: A Retrospective Analysis. World Neurosurg. 2023. PMID: 37393997. doi:10.1016/j.wneu.2023.06.110
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。