文献速递神经肿瘤

应用剪切波与磁共振弹性成像对脑肿瘤分级:系统综述与Meta分析

Applying Shear Wave and Magnetic Resonance Elastography to Grade Brain Tumors: Systematic Review and Meta-Analysis.
PubMed 文献 · World Neurosurg · 2023-07-11

该研究通过系统综述与Meta分析评估剪切波弹性成像(SWE)和磁共振弹性成像(MRE)能否预测脑膜瘤与胶质瘤级别。纳入8项研究,低级别肿瘤84例、高级别肿瘤92例。低级别肿瘤硬度高于高级别肿瘤(Cohen's D=-1.25;95%CI -1.88,-0.62),异质性中等(I²=67%;P=0.006)。结论认为弹性成像技术有潜力在术中及术后对肿瘤分级,但需更多研究评估其临床效用。

要点

  • 低级别脑肿瘤硬度高于高级别脑肿瘤(Cohen's D=-1.25;95%CI -1.88,-0.62)。
  • 异质性中等(I²=67%;P=0.006),控制发表年份或年龄后异质性降低。
  • 作者结论认为弹性成像技术有潜力在术中及术后对肿瘤分级,但需更多研究评估临床效用。

核心结论

  • 弹性成像技术有潜力在术中及术后对肿瘤进行分级。
  • 需要更多研究来评估这些技术的临床效用。

研究设计与样本

  • 系统综述与Meta分析,检索PubMed和Scopus数据库,检索时间为2022年2月10日至2022年3月2日。
  • 纳入8项研究,共包括低级别肿瘤患者84例(年龄42±13岁,71%为女性)和高级别肿瘤患者92例(年龄50±13岁,42%为女性)。

主要发现

  • 低级别肿瘤硬度高于高级别肿瘤(Cohen's D=-1.25;95%CI -1.88,-0.62)。
  • 观察到中等异质性(I²=67%;P=0.006),控制发表年份后异质性为I²=0.2%,控制年龄后异质性为I²=0.0%-17%。
  • 纳入研究中,参考标准及流程与时机领域的偏倚风险不明确或高偏倚风险的比例超过50%。

局限性

  • 异质性中等(I²=67%;P=0.006)。
  • 纳入研究中参考标准及流程与时机领域的偏倚风险不明确或高偏倚风险的比例超过50%。
  • 需要更多研究来评估这些技术的临床效用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Reports find that magnetic resonance elastography (MRE) and shear wave elastography (SWE) can classify intracranial tumors according to stiffness. However, systematic syntheses of these articles are lacking. In this report, a systematic review and meta-analysis was performed to evaluate whether SWE and MRE can predict meningioma and glioma grades. METHODS: PubMed and Scopus were searched between February 10, 2022. and March 2, 2022. using manual search criteria. Eight out of 106 non-duplicate records were included, encompassing 84 patients with low-grade tumors (age 42 ± 13 years, 71% female) and 92 patients with high-grade tumors (age 50 ± 13 years, 42% female). Standardized mean difference in stiffness between high-grade and low-grade tumors were measured using a forest plot. The I2, χ2, and t tests were performed, and bubble plots were constructed to measure heterogeneity. An adapted QUADAS-2 scale evaluated study quality. Additionally, a funnel plot was constructed, and an Egger's intercept test determined study bias. RESULTS: Low-grade tumors were stiffer than high-grade tumors (Cohen's D = -1.25; 95% CI -1.88, -0.62). Moderate heterogeneity was observed (I2 = 67%; P = 0.006) but controlling for publication year (I2 = 0.2%) and age (I2 = 0.0%-17%) reduced heterogeneity. Included studies revealed unclear or high bias for the reference standard and flow and timing (>50%). CONCLUSIONS: Elastography techniques have potential to grade tumors intraoperatively and postoperatively. More studies are needed to evaluate the clinical utility of these technologies.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Kumarapuram S, Yu R, Manchiraju P, et al. Applying Shear Wave and Magnetic Resonance Elastography to Grade Brain Tumors: Systematic Review and Meta-Analysis. World Neurosurg. 2023. PMID: 37442538. doi:10.1016/j.wneu.2023.07.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。