近红外光谱预测蛛网膜下腔出血后迟发性脑缺血及不良结局的诊断价值
本研究比较41例非创伤性蛛网膜下腔出血患者近红外光谱区域脑组织氧饱和度(rSO2)分布与迟发性脑缺血(DCI)及2个月功能结局的关系,并比较其与SAFIRE分级的预测价值。结果显示rSO2预测DCI的曲线下面积为0.77,预测良好结局的曲线下面积为0.86。
要点
- 41例患者中12例发生DCI,9例在60天时结局不良。
- rSO2预测DCI的曲线下面积为0.77,最佳截断值65%,灵敏度1.00,特异度0.45。
- rSO2预测良好结局的曲线下面积为0.86,最佳截断值63%,灵敏度1.00,特异度0.63。
核心结论
- 作者认为,对蛛网膜下腔出血患者进行近红外光谱rSO2监测可能改善对DCI和临床结局的预测。
研究设计与样本
- 本研究比较了蛛网膜下腔出血后有无DCI患者的rSO2分布,评估预测DCI和结局的最佳截断点,并与SAFIRE分级比较预测价值。
- 共纳入41例患者,其中12例发生DCI,9例在60天时结局不良。
主要发现
- 近红外光谱预测DCI的曲线下面积为0.77(95%置信区间0.62-0.92;P=0.0028),最佳截断值65%(灵敏度1.00;特异度0.45)。
- 近红外光谱预测良好结局的曲线下面积为0.86(95%置信区间0.74-0.98;P=0.0003),最佳截断值63%(灵敏度1.00;特异度0.63)。
- 回归分析显示,近红外光谱rSO2评分与SAFIRE分级互补。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Near-infrared spectroscopy (NIRS) is a noninvasive tool to monitor cerebral regional oxygen saturation. Impairment of microvascular circulation with subsequent cerebral hypoxia during delayed cerebral ischemia (DCI) is associated with poor functional outcome after subarachnoid hemorrhage (SAH). Therefore, NIRS could be useful to predict the risk for DCI and functional outcome. However, only limited data are available on NIRS regional cerebral tissue oxygen saturation (rSO2) distribution in SAH. The aim of this study was to compare the distribution of NIRS rSO2 values in patients with nontraumatic SAH with the occurrence of DCI and functional outcome at 2 months. In addition, the predictive value of NIRS rSO2 was compared with the previously validated SAFIRE grade (derived from Size of the aneurysm, Age, FIsher grade, World Federation of Neurosurgical Societies after REsuscitation). METHODS: In this study, the rSO2 distribution of patients with and without DCI after SAH was compared. The optimal cutoff points to predict DCI and outcome were assessed, and its predictive value was compared with the SAFIRE grade. RESULTS: Of 41 patients, 12 developed DCI, and 9 had unfavorable outcome at 60 days. Prediction of DCI with NIRS had an area under the curve of 0.77 (95% confidence interval 0.62-0.92; P = 0.0028) with an optimal cutoff point of 65% (sensitivity 1.00; specificity 0.45). Prediction of favorable outcome with NIRS had an area under the curve of 0.86 (95% confidence interval 0.74-0.98; P = 0.0003) with an optimal cutoff point of 63% (sensitivity 1.00; specificity 0.63). Regression analysis showed that NIRS rSO2 score is complementary to the SAFIRE grade. CONCLUSIONS: NIRS rSO2 monitoring in patients with SAH may improve prediction of DCI and clinical outcome after SAH.
引用
- van der Harst JJ, Elting JWJ, Bokkers RPH, et al. The Diagnostic Value of Near-Infrared Spectroscopy to Predict Delayed Cerebral Ischemia and Unfavorable Outcome After Subarachnoid Hemorrhage. World Neurosurg. 2023. PMID: 37454906. doi:10.1016/j.wneu.2023.07.033
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。