文献速递小儿神经外科与脑积水

达到平台期前的斜率:腰椎灌注试验获得的特发性正常压力脑积水阀门反应新预测指标

Slope until reaching the plateau: a new predictor of valve response obtained by lumbar infusion test for idiopathic normal pressure hydrocephalus.
PubMed 文献 · Acta Neurochir (Wien) · 2023-06-22

本研究回顾性分析110例疑似特发性正常压力脑积水行腰椎灌注试验并接受脑室腹腔分流术的患者,比较分流反应组与非反应组的阻力指数(Rout)、达到平台期时间(TRP)和达到平台期前斜率(SRP)。反应组Rout和SRP显著更高、TRP更短;SRP的AUC大于Rout但差异无统计学意义。作者认为SRP可作为分流反应预测指标,准确度可能优于Rout。

要点

  • 分流反应组SRP为0.049 mmHg/sec,非反应组为0.031 mmHg/sec,组间差异有统计学意义(p<0.001)。
  • SRP的AUC为0.763(95%CI 0.655-0.871,p<0.001),Rout的AUC为0.673(95%CI 0.595-0.801,p=0.008),两者差异无统计学意义(p=0.180)。
  • 作者认为SRP可作为脑室腹腔分流术反应的预测指标,其准确度可能优于Rout。

核心结论

  • SRP可被视为脑室腹腔分流术反应的预测指标,其准确度可能优于Rout;该变量可能有助于在疑似特发性正常压力脑积水患者中筛选分流候选者。

研究设计与样本

  • 回顾性研究,纳入110例疑似特发性正常压力脑积水、接受腰椎灌注试验并有脑室腹腔分流术指征的患者,分为分流反应组与非反应组。
  • 通过腰椎灌注试验获取Rout、TRP(从开始灌注至达到平台期的时间,以秒计)和SRP((平台期压力-开放压力)/TRP)。
  • 对Rout和SRP计算受试者工作特征曲线(ROC)及其曲线下面积(AUC)。

主要发现

  • 110例中86例为分流反应者(78.20%)。
  • 分流反应组Rout为17.02(14.45-20.23)mmHg/ml/min,非反应组为13.34(12.10-16.28)mmHg/ml/min,反应组更高,p=0.002。
  • 分流反应组SRP为0.049(0.043-0.054)mmHg/sec,非反应组为0.031(0.026-0.036)mmHg/sec,反应组更高,p<0.001。
  • 分流反应组TRP为641.28(584.83-697.73)秒,非反应组为777.65(654.03-901.27)秒,反应组更短,p=0.028。
  • SRP的AUC为0.763(95%CI 0.655-0.871,p<0.001),Rout的AUC为0.673(95%CI 0.595-0.801,p=0.008),两者差异无统计学意义(p=0.180)。

关键数值与推荐

  • 分流反应组Rout 17.02(14.45-20.23)mmHg/ml/min vs 非反应组13.34(12.10-16.28)mmHg/ml/min,p=0.002。
  • 分流反应组SRP 0.049(0.043-0.054)mmHg/sec vs 非反应组0.031(0.026-0.036)mmHg/sec,p<0.001。
  • 分流反应组TRP 641.28(584.83-697.73)秒 vs 非反应组777.65(654.03-901.27)秒,p=0.028。
  • SRP的AUC 0.763(95%CI 0.655-0.871,p<0.001) vs Rout的AUC 0.673(95%CI 0.595-0.801,p=0.008),AUC差异p=0.180。

临床怎么用

  • 作者认为SRP可作为脑室腹腔分流术反应的预测指标,其准确度可能优于Rout,可能有助于在疑似特发性正常压力脑积水患者中筛选分流候选者。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Diagnosis of idiopathic normal pressure hydrocephalus (iNPH) is based on clinical, radiological, and hydrodynamic data of cerebrospinal fluid (CSF) obtained by invasive methods such as lumbar infusion test, which is used to determine the resistance to CSF outflow (Rout). However, Rout has limitations, and its value as predictor of valve response is questioned. Other variables can be obtained by lumbar infusion test, such as the time to reach the plateau (TRP) and the slope until reaching the plateau (SRP). The objectives were to determine if SRP could be a predictor of response to ventriculoperitoneal shunt (VPS) and what variable (Rout versus SRP) would have greater predictive value. METHOD: Patients with probable iNPH who underwent a lumbar infusion test and were indicated for a VPS were retrospectively studied. Two groups were established, responders and non-responders. Rout, TRP (period between the start of infusion until reaching the plateau measured in seconds) and SRP ((plateau pressure-opening pressure)/TRP) were obtained. For Rout and SRP, the receiver operating curves (ROC) with its areas under the curve (AUC) were calculated. RESULTS: One hundred ten patients were included, being 86 responders (78.20%). Shunt responders had a significantly greater Rout (17.02 (14.45-20.23) versus 13.34 (12.10-16.28) mmHg/ml/min, p = 0.002) and SRP (0.049 (0.043-0.054) versus 0.031 (0.026-0.036) mmHg/sec, p < 0.001) and smaller TRP (641.28 (584.83-697.73) versus 777.65 (654.03-901.27) sec, p = 0.028) than non-responders. The AUC for SRP was greater than the AUC for Rout (0.763 (95 % CI 0.655-0.871, p < 0.001) versus 0.673 (95 % CI 0.595-0.801, p = 0.008), respectively), but the differences were not significant (p = 0.180). CONCLUSIONS: SRP could be considered predictor of response to VPS, and its accuracy tends to be better than Rout. So, this variable may be a useful tool to select shunt candidates among patients with probable iNPH.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Otero-Rodriguez A, Arandia-Guzman DA, Pascual-Argente D, et al. Slope until reaching the plateau: a new predictor of valve response obtained by lumbar infusion test for idiopathic normal pressure hydrocephalus. Acta Neurochir (Wien). 2023. PMID: 37347295. doi:10.1007/s00701-023-05670-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。