文献速递小儿神经外科与脑积水神经重症

外部脑室引流与脑室通路装置用于成人脑积水急诊管理的比较

Comparison of External Ventricular Drains with Ventricular Access Devices for the Emergency Management of Adult Hydrocephalus.
PubMed 文献 · World Neurosurg · 2023-06-26

本研究回顾性比较成人脑积水急性管理中外部脑室引流(EVD)与经脑室通路装置(VAD)经皮持续脑脊液引流,纳入179根引流管(EVD 76根、VAD 103根)。EVD非计划重返手术室更换或修正率更高(27/76,36% vs 4/103,4%,OR 13.4,95%CI 4.3-55.8),VAD感染率更高(13/103,13% vs 5/76,7%,OR 2.0,95%CI 0.65-7.7);多因素分析中感染与引流持续时间相关,与引流类型无关(VAD vs EVD OR 1.6,95%CI 0.5-6)。

要点

  • EVD非计划重返手术室更换或修正率高于VAD(36% vs 4%,OR 13.4)。
  • VAD感染率13% vs EVD 7%,OR 2.0,95%CI跨1,未达统计学显著。
  • 多因素分析中感染与引流持续时间相关,与引流类型无关。

核心结论

  • EVD非计划修正率高于VAD但感染率低于VAD,然而多因素分析中引流类型与感染无关。
  • 作者建议开展前瞻性比较,采用相似采样方案对比抗生素浸渍VAD与EVD,以评估急性脑积水哪种引流总体并发症率更低。

研究设计与样本

  • 回顾性 Review,纳入四年内因新诊断脑积水、脑脊液无感染而置入的全部脑室引流管,共179根(EVD 76根、VAD 103根)。
  • 比较EVD与VAD的感染率、重返手术室率和患者结局,并用多因素logistic回归探讨引流持续时间、采样频率、脑积水病因和导管位置的影响。

主要发现

  • EVD非计划重返手术室更换或修正27/76(36%),VAD为4/103(4%),OR 13.4,95%CI 4.3-55.8。
  • VAD感染13/103(13%),EVD感染5/76(7%),OR 2.0,95%CI 0.65-7.7。
  • EVD中91%为抗生素浸渍,VAD中98%为非浸渍。
  • 多因素分析中感染与引流持续时间相关:感染引流管感染前中位引流11天,非感染引流管总中位引流7天;感染与引流类型无关(VAD vs EVD OR 1.6,95%CI 0.5-6)。

临床怎么用

  • 作者建议开展前瞻性比较,采用相似采样方案对比抗生素浸渍VAD与EVD,以评估急性脑积水哪种引流总体并发症率更低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: We compared external ventricular drains (EVDs) with percutaneous continuous cerebrospinal fluid (CSF) drainage via ventricular access devices (VADs) for the acute management of hydrocephalus in adults. METHODS: This was a retrospective review of all ventricular drains inserted for a new diagnosis of hydrocephalus into noninfected CSF over four years. We compared infection rates, return to theatre, and patient outcome between EVDs and VADs. We explored the effect of duration of drainage, frequency of sampling, hydrocephalus aetiology, and catheter location on these outcomes using multivariable logistic regression modelling. RESULTS: We included 179 drains (76 EVDs and 103 VADs). EVDs were associated with a higher rate of unplanned return to theatre for replacement or revision (27/76, 36%, vs. 4/103, 4%, OR: 13.4 95%CI: 4.3-55.8). However, infection rates were higher in VADs (13/103, 13% vs. 5/76, 7%, OR: 2.0, 95%CI: 0.65-7.7). EVDs were 91% antibiotic impregnated whereas VADs were 98% nonimpregnated. In multivariable analysis, infection was associated with duration of drainage (median: 11 days prior to infection for infected drains vs. 7 days total for noninfected drains), but not drain type (VADs vs. EVDs OR: 1.6, 95%CI: 0.5-6). CONCLUSIONS: EVDs had a higher rate of unplanned revisions but a lower infection rate compared to VADs. However, in multivariable analysis choice of drain type was not associated with infection. We suggest a prospective comparison of antibiotic impregnated VADs and EVDs using similar sampling protocols to assess whether VADs or EVDs for acute hydrocephalus have a lower overall complication rate.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Mian SY, Mancuso-Marcello M, Kandasamy J, et al. Comparison of External Ventricular Drains with Ventricular Access Devices for the Emergency Management of Adult Hydrocephalus. World Neurosurg. 2023. PMID: 37380053. doi:10.1016/j.wneu.2023.06.091

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。