文献速递神经肿瘤

表观扩散系数直方图分析在鉴别微囊型脑膜瘤与颅内孤立性纤维性肿瘤中的应用价值

Utility of Apparent Diffusion Coefficient Histogram Analysis in Differentiating Microcystic Meningioma from Intracranial Solitary Fibrous Tumor.
PubMed 文献 · World Neurosurg · 2023-06-24

本研究回顾性纳入18例微囊型脑膜瘤(MM)和23例颅内孤立性纤维性肿瘤(SFT)患者,比较常规MRI特征及9项ADC直方图参数。SFT的平均ADC及ADC1、ADC10、ADC50、ADC90、ADC99均显著低于MM(均P<0.05),常规MRI特征无显著差异。ADC1为最佳鉴别参数,曲线下面积0.861,敏感度78.26%、特异度88.89%、准确率82.93%。

要点

  • SFT的ADC直方图多项参数(平均ADC、ADC1、ADC10、ADC50、ADC90、ADC99)显著低于MM。
  • 常规MRI特征在MM与SFT间无显著差异,两者表现重叠。
  • ADC1为最佳鉴别参数,AUC 0.861,敏感度78.26%、特异度88.89%、准确率82.93%。

核心结论

  • MM与SFT的常规MRI特征存在重叠,ADC直方图分析有助于两者鉴别,ADC1为鉴别性能最佳的最优参数。

研究设计与样本

  • 回顾性研究纳入18例微囊型脑膜瘤(MM)患者和23例颅内孤立性纤维性肿瘤(SFT)患者,比较常规MRI特征及9项ADC直方图参数。

主要发现

  • SFT的平均ADC、ADC1、ADC10、ADC50、ADC90、ADC99均显著低于MM(均P<0.05)。
  • SFT与MM在常规MRI特征及其他ADC直方图参数上均无显著差异(均P>0.05)。
  • ADC1鉴别MM与SFT的曲线下面积为0.861,敏感度78.26%、特异度88.89%、准确率82.93%。

关键数值与推荐

  • ADC1为鉴别MM与SFT的最优参数,曲线下面积0.861,敏感度78.26%、特异度88.89%、准确率82.93%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To investigate the possibility of histogram analysis of apparent diffusion coefficient (ADC) maps in differentiating microcystic meningioma (MM) from intracranial solitary fibrous tumor (SFT). METHODS: Eighteen patients with MM and 23 patients with SFT were enrolled in this retrospective study. Conventional magnetic resonance imaging (MRI) features and 9 ADC histogram parameters (including mean, first (ADC1), 10th (ADC10), 50th (ADC50), 90th (ADC90), and 99th (ADC99) percentiles ADC, as well as variance, skewness, and kurtosis) between MM and SFT were compared. The diagnostic performance of the optimal parameter was determined by the receiver operating characteristic analysis. RESULTS: SFT showed a significantly lower mean, ADC1, ADC10, ADC50, ADC90, and ADC99 than MM (all P < 0.05), while no significant difference was found in conventional MRI features or other ADC histogram parameters (all P > 0.05). ADC1 was identified as the optimal parameter in differentiating between MM and SFT, which achieved an area under the curve of 0.861, with sensitivity, specificity, and accuracy of 78.26%, 88.89%, and 82.93%, respectively. CONCLUSIONS: MM and SFT show overlapping conventional MRI features. ADC histogram analysis helps to differentiate between MM and SFT, with ADC1 being the optimal parameter with the best discrimination performance.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Liu X, Han T, Wang Y, et al. Utility of Apparent Diffusion Coefficient Histogram Analysis in Differentiating Microcystic Meningioma from Intracranial Solitary Fibrous Tumor. World Neurosurg. 2023. PMID: 37356483. doi:10.1016/j.wneu.2023.06.073

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。