文献速递脑血管病外科

开发用于立体定向放射外科高精度的血管造影引导指示器

Development of an Angiography Guide Indicator for Stereotactic Radiosurgery for High Precision.
PubMed 文献 · World Neurosurg · 2023-06-01

本研究开发了一种用于立体定向放射外科的血管造影引导指示器,通过在现有指示器上绘制中线并固定连接「+」与「X」中心的导丝进行改良。基于是否使用该引导指示器,各拍摄10次血管造影正位和侧位图像并进行统计分析。结果显示新型指示器的精度优于传统指示器,作者认为该引导指示器可在立体定向放射外科中提供有意义的信息。

要点

  • 开发了一种连接「+」与「X」中心的血管造影引导指示器。
  • 传统正位和侧位指示器均值±标准差分别为10.22±0.53 mm和9.02±0.33 mm。
  • 新型正位和侧位指示器均值±标准差分别为10.3±0.57 mm和8.92±0.23 mm。

核心结论

  • 使用本研究开发的铅指示器相比传统指示器具有更高的准确性和精确度,该引导指示器可能为立体定向放射外科提供有意义的信息。

研究设计与样本

  • 绘制中线并附着引导线使现有血管造影引导指示器的「+」与「X」中心相交,用胶带固定连接「+」与「X」的引导线;基于有无引导指示器,各拍摄10次血管造影正位和侧位图像并进行统计分析。

主要发现

  • 传统正位指示器均值±标准差为10.22±0.53 mm,传统侧位指示器为9.02±0.33 mm。
  • 新型正位指示器均值±标准差为10.3±0.57 mm,新型侧位指示器为8.92±0.23 mm。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Stereotactic radiosurgery (SRS) is effectively used for treating various cerebrovascular diseases, including arteriovenous malformations. As image-based surgery is the gold standard technique in SRS, the quality of stereotactic angiography images greatly influences the surgical approach for cerebrovascular diseases. Despite several studies in the relevant literature, research on auxiliary devices, including angiography indicators used for cerebrovascular disease surgeries, is limited. Thus, the development of angiographic indicators may provide meaningful data for stereotactic surgery. METHODS: A centerline was drawn, and a guideline was attached such that the "+" and "X" centers of the existing angiography guide indicator intersect. Further, a guideline wire connecting "+" and "X" was fixed using a tape. Based on the presence or absence of the guide indicator, angiography anterior-posterior (AP) and lateral (LAT) images were taken 10 times each, and statistical analysis was performed. RESULTS: The average and standard deviation of the conventional AP and LAT indicators were 10.22 ± 0.53 mm and 9.02 ± 0.33 mm, and those of the developed AP and LAT indicators were 10.3 ± 0.57 mm and 8.92 ± 0.23 mm, respectively. CONCLUSIONS: The results confirmed that the use of the lead indicator developed in this study provides higher accuracy and precision compared to that of the use of the conventional indicator. Furthermore, the developed guide indicator may provide meaningful information during SRS.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Kim B, Yang JU, Choi HJ, et al. Development of an Angiography Guide Indicator for Stereotactic Radiosurgery for High Precision. World Neurosurg. 2023. PMID: 37268189. doi:10.1016/j.wneu.2023.05.100

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。