应用视频运动放大技术揭示自发性鼓膜位移作为脑部病变患者颅内压的间接测量指标

Applying video motion magnification to reveal spontaneous tympanic membrane displacement as an indirect measure of intracranial pressure in patients with brain pathologies.
PubMed 文献 · Acta Neurochir (Wien) · 2023-06-27

本研究对9例植入颅内压传感器的成人脑部病变患者(6例创伤性脑损伤、3例动脉瘤性蛛网膜下腔出血)进行回顾性分析,采用基于相位的视频运动放大算法提取自发性脉搏鼓膜位移波形,并与有创测量的颅内压进行比较。结果显示鼓膜位移脉冲振幅与平均颅内压(rS=0.73;p=0.025)及颅内压脉冲振幅(rS=0.88;p=0.002)显著相关。作者认为该算法有潜力用于无创检测颅内压升高风险,但需在更大样本中进一步研究。

要点

  • 鼓膜位移脉冲振幅与平均颅内压显著相关(rS=0.73;p=0.025)。
  • 鼓膜位移脉冲振幅与颅内压脉冲振幅显著相关(rS=0.88;p=0.002)。
  • 作者认为视频运动放大算法有潜力无创检测颅内压升高风险,但需更大样本进一步研究。

核心结论

  • 研究提示鼓膜位移脉冲振幅随平均颅内压和颅内压脉冲振幅升高而增大。
  • 使用视频运动放大算法估计鼓膜位移脉冲振幅有潜力无创检测颅内压升高风险,但需在更大样本中进一步研究。

研究设计与样本

  • 回顾性研究,纳入9例成人脑部病变患者(6例创伤性脑损伤、3例动脉瘤性蛛网膜下腔出血),中位年龄44(29-53)岁,于2021年10月至2022年10月入住弗罗茨瓦夫医科大学重症监护室并植入颅内压传感器。
  • 使用带摄像头的便携式耳镜检查鼓膜并录像,由自定义视频运动放大算法分析;颅内压用脑实质内传感器监测,动脉血压经桡动脉置管测量;颅内压、动脉血压和鼓膜位移视频同步采集。
  • 颅内压脉冲振幅、动脉血压脉冲振幅和鼓膜位移脉冲振幅通过快速傅里叶变换在心率相关频率范围内估计。

主要发现

  • 鼓膜位移脉冲振幅与平均颅内压显著相关(rS=0.73;p=0.025)。
  • 鼓膜位移脉冲振幅与颅内压脉冲振幅显著相关(rS=0.88;p=0.002)。
  • 年龄不是该关联的显著调节因素。
  • 鼓膜位移脉冲振幅与平均动脉血压、心率或动脉血压脉冲振幅之间无显著关系。

局限性

  • 作者指出需在更大样本患者中进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The observation of tympanic membrane displacement (TMD) opens up the possibility of indirect intracranial pressure (ICP) estimation. In this study, we applied a phase-based video motion magnification (VMM) algorithm to reveal spontaneous pulse TMD waveforms (spTMD) and compare them with invasively measured ICP in patients with intracranial pathologies. METHODS: Nine adults (six traumatic brain injury and three aneurysmal subarachnoid haemorrhage; median age 44 (29-53) years admitted to the intensive care unit of Wroclaw Medical University between October 2021 and October 2022 with implanted ICP sensors were included in this retrospective study. Video recordings of the tympanic membrane were performed using a portable otoscope with a video camera and analysed by a custom-written VMM algorithm. ICP was monitored using intraparenchymal sensors and arterial blood pressure (ABP) was measured in the radial arterial lines. ICP, ABP, and spTMD videos were captured simultaneously. The pulse amplitudes of ICP (Amp_ICP), ABP (Amp_ABP) and spTMD (Amp_spTMD) were estimated using fast Fourier transform within the heart rate (HR)-related frequency range. RESULTS: Amp_spTMD was significantly correlated with mean ICP (rS = 0.73; p = 0.025) and with Amp_ICP (rS = 0.88; p = 0.002). Age was not a significant moderator of this association. There were no significant relationships between Amp_spTMD and either mean ABP, HR, or Amp_ABP. CONCLUSIONS: The study suggests that Amp_spTMD increases with the increase in mean ICP and Amp_ICP. Estimation of Amp_spTMD using the VMM algorithm has the potential to allow for non-invasive detection of the risk of elevated ICP; however, further investigation in a larger group of patients is required.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Uryga A, Kazimierska A, Popek M, et al. Applying video motion magnification to reveal spontaneous tympanic membrane displacement as an indirect measure of intracranial pressure in patients with brain pathologies. Acta Neurochir (Wien). 2023. PMID: 37369772. doi:10.1007/s00701-023-05681-9