高位凸面蛛网膜下腔紧缩是特发性正常压力脑积水的显著特征
本研究旨在定义高位凸面蛛网膜下腔紧缩(THC)并比较其体积、百分比和指数在特发性正常压力脑积水(iNPH)患者与健康对照间的差异。研究对43例iNPH患者和138例健康对照的3D T1加权和T2加权磁共振图像进行分割测量,结果发现高位凸面蛛网膜下腔体积与脑室体积比值<0.6是检测THC的最佳指标。
要点
- THC定义为侧脑室体部上方高位凸面蛛网膜下腔减少,并明确了前、后、侧边界。
- 高位凸面蛛网膜下腔体积与脑室体积比值<0.6是3D T1和T2加权图像上检测THC的最佳指标。
- 该比值优于体积和体积百分比,有助于提高iNPH诊断准确性。
核心结论
- 为改善iNPH诊断准确性,本研究明确了THC的定义,并提出高位凸面蛛网膜下腔体积与脑室体积比值<0.6为检测THC的最佳指标。
研究设计与样本
- 研究纳入43例iNPH患者和138例健康对照,根据THC定义从3D T1加权和T2加权磁共振图像上分割并测量高位凸面蛛网膜下腔的体积和百分比。
主要发现
- 与体积和体积百分比相比,高位凸面蛛网膜下腔体积与脑室体积比值<0.6在3D T1加权和T2加权磁共振图像上均为检测THC的最敏感指标。
关键数值与推荐
- THC定义为侧脑室体部上方高位凸面蛛网膜下腔减少,前界位于经胼胝体膝部前缘垂直于前连合-后连合(AC-PC)线的冠状面,后界位于双侧扣带缘沟后部,侧界位于经AC与PC中点垂直于AC-PC线的冠状面上距中线3 cm处。
- 高位凸面蛛网膜下腔体积与脑室体积比值<0.6被提出作为THC检测的最佳指标。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The presence of tightened sulci in the high-convexities (THC) is a key morphological feature for the diagnosis of idiopathic normal pressure hydrocephalus (iNPH), but the exact localization of THC has yet to be defined. The purpose of this study was to define THC and compare its volume, percentage, and index between iNPH patients and healthy controls. METHODS: According to the THC definition, the high-convexity part of the subarachnoid space was segmented and measured the volume and percentage from the 3D T1-weighted and T2-weighted magnetic resonance images in 43 patients with iNPH and 138 healthy controls. RESULTS: THC was defined as a decrease in the high-convexity part of the subarachnoid space located above the body of the lateral ventricles, with anterior end on the coronal plane perpendicular to the anterior commissure-posterior commissure (AC-PC) line passing through the front edge of the genu of corpus callosum, the posterior end in the bilateral posterior parts of the callosomarginal sulci, and the lateral end at 3 cm from the midline on the coronal plane perpendicular to the AC-PC line passing through the midpoint between AC and PC. Compared to the volume and volume percentage, the high-convexity part of the subarachnoid space volume per ventricular volume ratio < 0.6 was the most detectable index of THC on both 3D T1-weighted and T2-weighted magnetic resonance images. CONCLUSIONS: To improve the diagnostic accuracy of iNPH, the definition of THC was clarified, and high-convexity part of the subarachnoid space volume per ventricular volume ratio <0.6 proposed as the best index for THC detection in this study.
引用
- Yamada S, Ito H, Matsumasa H, et al. Tightened Sulci in the High Convexities as a Noteworthy Feature of Idiopathic Normal Pressure Hydrocephalus. World Neurosurg. 2023. PMID: 37245671. doi:10.1016/j.wneu.2023.05.077
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。