文献速递功能神经外科

立体定向机器人辅助MRI引导激光间质热疗丘脑毁损术治疗药物难治性帕金森病震颤:技术说明与2例初步疗效

Stereotactic robot-assisted MRI-guided laser interstitial thermal therapy thalamotomy for medically intractable Parkinson's disease tremor: technical note and preliminary effects on 2 cases.
PubMed 文献 · Acta Neurochir (Wien) · 2023-05-04

本文描述2例药物难治性帕金森病震颤患者,接受立体定向机器人辅助MRI引导激光间质热疗(MRIg-LITT)丘脑毁损术,术中全麻下进行电生理测试。术后3个月随访,两例震颤评分(TRS)均改善75%,生活质量(39项PD问卷)分别改善32.54%和38%,均无并发症。作者认为对于不适合DBS的患者,该技术可能是可行选择,但需更大样本和更长随访证实。

要点

  • 2例药物难治性PD震颤患者接受机器人辅助MRIg-LITT丘脑毁损术,术中全麻下电生理测试,均无并发症。
  • 术后3个月随访,两例TRS震颤评分均改善75%,生活质量(39项PD问卷)分别改善32.54%和38%。
  • 作者认为对于不适合DBS的药物难治性PD震颤患者,该技术可能是可行选择,但需更大样本和更长随访证实。

核心结论

  • 对于不适合DBS的药物难治性PD震颤患者,采用立体定向机器人、术中电生理测试和实时MRI引导激光消融的丘脑毁损术可能是可行治疗选择。
  • 作者指出需要更大样本量和更长随访期的进一步研究来证实这些初步结果。

研究设计与样本

  • 技术说明与2例病例报告。
  • 2例药物难治性PD震颤患者接受立体定向机器人辅助MRIg-LITT丘脑毁损术,全麻下进行术中电生理测试。
  • 术前和术后采用Fahn-Tolosa-Marin震颤评定量表(TRS)评估震颤评分,采用39项PD问卷评估生活质量。

主要发现

  • 术后3个月随访,两例患者主观上和根据TRS均显示震颤症状显著改善(两例均为75%)。
  • 根据39项PD问卷,两例患者生活质量分别改善32.54%和38%。
  • 两例患者均接受MRIg-LITT丘脑毁损术,无并发症。

局限性

  • 作者指出需要更大样本量和更长随访期的进一步研究来证实这些初步结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Medically intractable Parkinson's disease (PD) tremor is a common difficult clinical situation with major impact on patient's quality of life (QOL). Deep brain stimulation (DBS) is an effective therapy but is not an option for many patients. Less invasive lesional brain surgery procedures, such as thalamotomy, have proven to be effective in these indications. Here, we describe the technical nuances and advantages of stereotactic robot-assisted MRI-guided laser interstitial thermal therapy (MRIg-LITT) thalamotomy for medically intractable PD tremor. METHOD: We describe 2 patients with medically intractable PD tremor treated with stereotactic robot-assisted MRIg-LITT thalamotomy performed under general anesthesia with intraoperative electrophysiological testing. Pre and postoperative tremor scores were assessed using the Fahn-Tolosa-Marin tremor rating scale (TRS). RESULTS: At 3-month follow-up, both patients demonstrated significant improvement in tremor symptoms subjectively and according to the TRS (75% for both). Patients also had substantial improvements in their QOL (32.54% and 38%) according to the 39-item PD questionnaire. Both patients underwent uncomplicated MRIg-LITT thalamotomy. CONCLUSIONS: In patients with medically intractable PD tremor who are unsuitable candidates for DBS, thalamotomy utilizing a stereotactic robot, intraoperative electrophysiological testing, and laser ablation with real-time MRI guidance may be a viable treatment option. However, further studies with larger sample sizes and longer follow-up periods are necessary to confirm these preliminary results.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Aubignat M, Tir M, Ouendo M, et al. Stereotactic robot-assisted MRI-guided laser interstitial thermal therapy thalamotomy for medically intractable Parkinson's disease tremor: technical note and preliminary effects on 2 cases. Acta Neurochir (Wien). 2023. PMID: 37140648. doi:10.1007/s00701-023-05614-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。